Teleflex
3015 Carrington Mill Boulevard, Morrisville, NC 27560
PHONE: (866) 246-6990 | FAX: (866) 804-9881
Balloons / PTCA Balloons
View Chart| Company Name | Product Name | Nominal Pressure (atm) | Rated Burst Pressure (atm) | Guidewire Compatibility (inch) | Shaft Length (cm) | Sheath Compatibility (F) | Balloon Diameters (mm) | Balloon Lengths (mm) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| Teleflex | Pantera Pro | 7 | 14 | 0.014 | 140 | 5 | 1.25, 1.5, 2, 2.5, 3, 3.5, 4 | 6, 10, 15, 20, 25, 30 | Balloon and tip coating: 1.25–2 mm hydrophilic; 2.5–4 mm hydrophobic |
| Teleflex | Glider PTCA Balloon Catheter | 8 (2.5-3 mm), 9 (3.5 mm), 11 (1.5–2 mm) | 14 (3.5 mm), 16 (1.5–3 mm) | 0.014 | 135 | 6 | 1.5, 2, 2.5, 3, 3.5 | 4, 8, 12, 20 | – |
| Teleflex | Pantera Leo | 14 | 18–20 | 0.014 | 145 | 5 | 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 | 8, 12, 15, 20, 30 | Noncompliant balloon |
Advertisement
Advertisement
Catheters / Angiographic Catheters
View Chart| Company Name | Product Name | Type (Braided/Nonbraided) | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Radiopaque Tip (Yes/No) | Variety of Selective Shapes |
|---|---|---|---|---|---|---|---|
| Teleflex | Arrow Balloon Wedge-Pressure | Nonbraided | 4, 5, 6, 7, 8 | 60, 90, 110 | 0.021–0.038 | No | Single- and double-lumen catheters; selection of inflated balloon diameters from 6 to 12 mm |
| Teleflex | Arrow Berman Catheters | Nonbraided | 4, 5, 6, 7, 8 | 50, 60, 70, 80, 90, 110 | 0.021–0.038 | No | Standard Berman catheter is indicated for pulmonary angiography, balloon occlusion femoral angiography (BOFA), and right heart pressure measurements; reverse Berman catheter is indicated for balloon occlusion pulmonary angiography (BOPA) |
| Teleflex | Arrow Thermodilution (Four Lumen and Five Lumen with Infusion) | Nonbraided | 5, 6, 7, 7.5 | 80, 110 | 0.021–0.038 | No | Four and five lumen catheters |
| Teleflex | Langston Dual Lumen Catheters | Braided | 6, 7 | 102, 110, 125 | – | Yes, plus five markerbands on one version | 145° pigtail and multipurpose with inner and outer lumen side holes |
Catheters / Microcatheters
View Chart| Company Name | Product Name | Type of Catheter Construction | Proximal Size (F) | Middle Size (F) | Distal Size (F) | Catheter Working Length (cm) | Catheter Endhole ID (inch) | Recommended Guidewire Size (inch) | Radiopaque Tip (Yes/No) | Hydrophilic Coating (Yes/No) |
|---|---|---|---|---|---|---|---|---|---|---|
| Teleflex | Turnpike Gold Catheter | Hybrid multilayer: dual bidirectional coils with inner braid and external nylon spiral coil | 2.9 | 2.9 | 2.1 | 135 | 0.0165 | 0.014 | Yes, gold-plated tip | Yes |
| Teleflex | Twin-Pass Torque Dual Access Catheter | Dual-lumen catheter | 3.5 X 3.5 | – | 2.1 | 135 | 0.017 | 0.014 (RX and OTW) | Yes, two markerbands | Yes |
| Teleflex | Twin-Pass Dual Access Catheter | Dual-lumen catheter | 3 | 3.5 | 2 | 135 | 0.017 | 0.014 (RX and OTW) | Yes, two markerbands | Yes |
| Teleflex | Turnpike Spiral Catheter | Hybrid multilayer: dual bidirectional coils with inner braid and external nylon spiral coil | 2.9 | 2.9 | 1.6 | 135, 150 | 0.0165 | 0.014 | Yes, tungsten-loaded tip | Yes |
| Teleflex | Turnpike LP Catheter | Hybrid multilayer: dual bidirectional coils with inner braid | 2.9 | 2.2 | 1.6 | 135, 150 | 0.0165 | 0.014 | Yes, tungsten-loaded tip | Yes |
| Teleflex | Turnpike Catheter | Hybrid multilayer: dual bidirectional coils with inner braid | 2.9 | 2.6 | 1.6 | 135, 150 | 0.0165 | 0.014 | Yes, tungsten-loaded tip | Yes |
| Teleflex | SuperCross Microcatheter OTW - 0.014 Straight and Flexible Tip | Braided | 2.5 | – | 1.8 | 130, 150 | 0.017 | 0.014 | Yes, one markerband | Yes |
| Teleflex | SuperCross Microcatheter OTW - 0.014 Angled Tips: 45°, 90°, 120°, and 90° Extended Tip | Dual coil design, platinum/tungsten coil tip | 3.2 | – | 2.4 | 130, 150 | 0.017 | 0.014 | Yes, platinum/tungsten coil tip | Yes |
| Teleflex | Minnie Support Catheter 0.014 | Polymer | 3.1 | 2 | 1.6 | 135, 150 | – | 0.014 | No; three radiopaque marker bands near distal tip | Yes |
Catheters / Specialty Catheters
View Chart| Company Name | Product Name | Catheter Size (F) | Working Length (cm) | Minimum Guiding Catheter ID (inch) | Comments |
|---|---|---|---|---|---|
| Teleflex | GuideLiner V3 Catheter | 5, 5.5, 6, 7, 8 | 150 | ≥ 0.056 (5 F); ≥ 0.066, ≥ 0.070 (6F); ≥ 0.078 (7 F); ≥ 0.088 (8 F) | Half-pipe design for seamless collar transition; this rapid-exchange, coaxial mother-and-child guide extension is delivered through standard guide catheters, resulting in an ID approximately one F size smaller than the guide catheter; used to access discrete regions of the coronary and/or peripheral vasculature and to facilitate placement of interventional devices |
| Teleflex | Twin-Pass Torque Dual Access Catheter | 3.5 X 3.5 | 135 | 0.014 (RX and OTW) | Access or delivery while maintaining wire position |
| Teleflex | Twin-Pass Dual Access Catheter | 3.5 | 135 | ≥ 0.066 (≥ 6 F) | Dual-lumen catheter with two independent 0.014-inch lumens; for guidewire access, guidewire support, and/or the delivery of contrast or medication |
| Teleflex | Turnpike Spiral Catheter | Distal 1.6 (tip), 2.9 (shaft); proximal: 2.9 | 135, 150 | ≥ 0.056 (≥ 5 F) | The same unique multilayer shaft construction and soft polymer tip as the Turnpike catheter; incorporates a nylon outer coil on the distal 2 cm of the catheter for additional rotational advancement |
| Teleflex | Turnpike LP Catheter | Distal: 1.6 (tip), 2.2 (shaft); proximal: 2.9 | 135, 150 | 0.056 (≥ 5 F) | Low profile with greater tip and distal shaft flexibility for advancement through extreme tortuosity |
| Teleflex | Turnpike Gold Catheter | Distal: 2.1 (tip), 2.9 (shaft); proximal: 2.9 | 135 | ≥ 0.056 (≥ 5 F) | The same unique multilayer shaft construction as the Turnpike catheter; incorporates a metal, threaded, gold-plated tip for enhanced rotational advancement |
| Teleflex | Turnpike Catheter | Distal: 1.6 (tip), 2.6 (shaft); proximal: 2.9 | 135, 150 | ≥ 0.056 (≥ 5 F) | Unique, multilayer shaft design and soft polymer tip that provide superior torque, flexibility, and tracking over a 0.014-inch guidewire for complex coronary and peripheral interventions |
| Teleflex | TrapLiner Catheter | 6, 7, 8 | 150 | 0.070 (6 F), 0.078 (7 F), 0.088 (8 F) | Guide extension catheter with trapping capabilities |
| Teleflex | SuperCross Microcatheter OTW - 0.014 Straight and Flexible Tip | Distal: 1.8; proximal: 2.5 | 130, 150 | 0.014 | Low-profile, hydrophilic-coated, braided OTW microcatheter with straight tip and flexible tip options provides support when navigating tortuous anatomy and bifurcated vessels |
| Teleflex | SuperCross Microcatheter OTW - 0.014 Angled Tips: 45°, 90°, 120°, and 90° Extended Tip | Distal: 2.4; proximal: 3.2 | 130, 150 | 0.014 | Low-profile, hydrophilic-coated, OTW microcatheter is available in multiple tip angle options (45°, 90°, 120°, 90° extended tip) with dual coil design for good torque response and delivery into branched anatomy |
| Teleflex | Minnie Support Catheter 0.035 | Distal: 3.8; proximal: 4.8 | 65, 90, 135, 150 | 0.063 | Hydrophilic coated; its smoothly tapered distal tip combined with a low crossing profile and fully embedded radiopaque markers are intended to provide guidewire support and exchange or delivery of therapeutic agents |
| Teleflex | Minnie Support Catheter 0.018 | Distal: 2.3; proximal: 3.4 | 90, 135, 150 | 0.044 | Hydrophilic coated; its smoothly tapered distal tip combined with a low crossing profile and fully embedded radiopaque markers are intended to provide guidewire support and exchange or delivery of therapeutic agents |
| Teleflex | Minnie Support Catheter 0.014 | Distal: 2; proximal: 3 | 135, 150 | 0.039 | Hydrophilic coated; its smoothly tapered distal tip combined with a low crossing profile and fully embedded radiopaque markers are intended to provide guidewire support and exchange or delivery of therapeutic agents |
| Teleflex | GuideLiner Coast Catheter | 5.5, 6, 7, 8 | 150 | 0.066, 0.070, 0.078, 0.088 | – |
Sheaths / Special Access Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip (Yes/No) | Type of Special Access |
|---|---|---|---|---|---|---|---|
| Teleflex | VSI De-Clot Micro-HV Introducer Kits | 5, 6, 7 | 4 | 0.018–0.038 compatible | Straight | Yes | Access to declotting dialysis grafts and fistulas |
| Teleflex | VSI StraitSet Micro-Introducer Kit | 6 | 20 | 0.018–0.038 compatible | Straight | Yes | Percutaneous introduction and placement of catheters and guidewires |
| Teleflex | VSI Pedal Micro-Introducer Kit | 2.3 | 10 | 0.018 | Curved | No | Percutaneous introduction of up to a 0.018-inch guidewire into the vascular system following a small gauge needle stick |
| Teleflex | VSI Micro-Introducer Kits | 4, 5 | 10, 15, 30 | 0.018–0.038 compatible | Curved or straight | No | Percutaneous introduction of catheter or guidewire into vascular system following a small-gauge needle stick |
| Teleflex | Super Arrow-Flex Transseptal Access Sheath Introducer Set | 8 | 61 | – | Straight | Yes | Transseptal |
| Teleflex | Super Arrow-Flex Carotid Access Sheath Introducer Set | 7 | 90 | – | Straight | Yes | Carotid |
| Teleflex | OptiSeal Valved Peelable Introducer | 6–12 | 13, 25 | 0.035 | Straight | No | Pacing lead implants, PICC lines, and central venous catheter implants |
| Teleflex | GrebSet Micro-Introducer Kit | 5 | 30, 45 | 0.018–0.038 compatible | Curved | Yes | Percutaneous introduction and placement of catheters and guidewires |
| Teleflex | Arrow Radial Access Sheath Kits | 4, 5, 6 | 7, 11, 24 | 0.018 | Straight | Yes | Radial |
| Teleflex | Super Arrow-Flex Renal Access Sheath Introducer Sets | 6, 7 | 45 | 0.035–0.038 | Curved, 90° | Yes | Renal |
Sheaths / Standard Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip (Yes/No) |
|---|---|---|---|---|---|---|
| Teleflex | Arrow Percutaneous Sheath Introducer Kits (Adult) | 4–9 | 11 | 0.035 | Straight | Yes |
| Teleflex | Arrow Percutaneous Sheath Introducer Kits (Pediatric) | 4–6 | 7.5 | 0.021 | Straight | Yes |
| Teleflex | Arrow-Flex PSI (With Arrow Raulerson Syringe and Cath-Gard Catheter Contamination Guards; With and Without ArrowGard) | 6, 7, 8, 8.5, 9 | 7, 10 | 0.025–0.035 | Straight | Yes |
Stents / Bioabsorbable Polymer Drug-Eluting Stents
View Chart| Company Name | Product Name | Drug Delivered | Material Used | Polymer Type | Maximum Guidewire Size (inch) | Introducer Size (F) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|---|---|---|
| Teleflex | Orsiro Mission | Sirolimus | Cobalt chromium | PLLA | 0.014 | 5 | 2.25, 2.5, 2.75, 3, 3.5, 4 | 9, 13, 15, 18, 22, 26, 30, 35, 40 | 140 | Indicated for improving coronary luminal diameter in patients, including those with diabetes mellitus, with symptomatic heart disease, stable angina, unstable angina, non–ST-segment elevation myocardial infarction or documented silent ischemia due to atherosclerotic lesions in the native coronary arteries with a reference vessel diameter of 2.25 to 4 mm and a lesion length of ≤ 36 mm |
Wires / Interventional CTO/Specialty Wires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type | Coating Type (Hydrophilic or Hydrophobic) | Comments |
|---|---|---|---|---|---|---|---|
| Teleflex | PiggyBack Wire Converter | Polymer catheter wire converter | 0.035 (OD) | 145 | Radiopaque marker embedded in distal tip | Hydrophilic | Wire converter with sliding lock securely fastens onto any standard 0.014-inch wire and converts it to a 0.035-inch wire platform |
| Teleflex | R350 Guidewire | Externalization wire | 0.013 | 350 | Nitinol core-to-tip; gold-plated tungsten coil; straight tip | PTFE (proximal: 150 cm); hydrophilic (distal: 200 cm) | – |
| Teleflex | Raider Guidewire | Specialty wire | 0.014 | 200, 300 | Stainless steel core-to-tip; 10-cm platinum coil; straight tip | PTFE (proximal); hydrophilic (distal) | Black polymer jacket covering the coil tip |
Wires / Interventional Workhorse Wires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type | Coating Type (Hydrophilic or Hydrophobic) | Comments |
|---|---|---|---|---|---|---|---|
| Teleflex | Spectre Guidewire | Workhorse wire | 0.014 | 190, 300 | Stainless steel-to-nitinol core-to-tip; straight tip | PTFE (proximal); hydrophilic (distal) | – |
Other Devices / Assisted Compression Devices
View Chart| Company Name | Product Name | Type | Puncture Size (F) | Maximum Wire Compatibility | Comments |
|---|---|---|---|---|---|
| Teleflex | D-Stat Dry Silver Clear Topical Hemostat | Thrombin-based topical hemostasis pad with clear bandage | 4–6 | – | Hemostatic pad with the clotting power of thrombin; used as an adjunct to manual compression and is provided with a clear bandage; contains silver chloride to prevent microorganisms commonly encountered in the clinical setting from colonizing on the pad |
| Teleflex | D-Stat Dry Silver Topical Hemostat | Thrombin-based topical hemostasis pad with bandage | 4–6 | – | Hemostatic pad with the clotting power of thrombin; used as an adjunct to manual compression; contains silver chloride to prevent microorganisms commonly encountered in the clinical setting from colonizing on the pad |
| Teleflex | D-Stat Flowable Hemostat | Flowable thrombin and collagen hemostat | All | – | Thick, yet flowable hemostat that can be used topically on sources of active bleeding; also indicated for prepectoral pocket hemostasis after pulse generator implantation |
| Teleflex | D-Stat Rad-Band Topical Hemostat | Mechanical compression device with thrombin that is designed to facilitate hemostasis of radial punctures | All | – | Adjustable radial compression band that consists of a nonwoven pad containing thrombin, an adjustable strap, and attached foam comfort pads |
| Teleflex | Vasc Band Hemostat | Hemostasis device | All | – | Inflatable hemostasis device consisting of a soft, adjustable plastic strap, compression balloon, and proprietary inflation syringe |
| Teleflex | D-Stat 2 Dry Topical Hemostat | Thrombin-based topical hemostasis pad that can be split in half | 4–6 | – | Two-bandage version of the D-Stat Dry that is scored and can be separated in half for application on two separate puncture sites |
| Teleflex | Accumed LP Wrist Positioning Splint | Radial positioning and stabilization device | – | – | Low-profile version of the Accumed II with greater wrist extension, a longer hand strap, and standard base |
| Teleflex | Accumed II Wrist Positioning Splint | Radial positioning and stabilization device | – | – | Single-use splint that promotes optimal wrist angle for arterial access and minimizes unwanted hand and arm movement before, during, and after a transradial procedure |
| Teleflex | D-Stat Clamp Topical Hemostat Accessory | Thrombin-based topical hemostasis pad with comfort pad and coupling device | 4–6 | – | Includes a hemostatic pad with the clotting power of thrombin; configured for attachment to many standard compression devices |
Other Devices / Closure Devices
View Chart| Company Name | Product Name | Type | Puncture Size (F) | Maximum Wire Compatibility (inch) | US FDA Indicated Use | Comments |
|---|---|---|---|---|---|---|
| Teleflex | Manta Vascular Closure Device | Bioresorbable implant | Following the use of 10–20 F device or sheaths (12–25 F OD) | 0.035 | Indicated for closure of femoral artery access sites while reducing time to hemostasis following the use of 10–20-F devices or sheaths (12–25-F OD) in endovascular catheterization procedures | Designed specifically for closure of large bore femoral artery access sites; easy positioning without the need for preclosure; simple deployment with help from auditory and visual cues and a reliable closure using a single device |
Other Devices / Intra-Aortic Balloon Pumps
View Chart| Company Name | Product Name | Catheter Size (F) | Balloon Size Volume (mL) | Arterial Pressure Lumen Diameter (inch) | Sheath Size (F) | Insertable Length (cm) | Guidewire Size (inch) | Distal Marker Length (mm) | Proximal Marker Length (mm) | Fiber Optic Pressure Sensing |
|---|---|---|---|---|---|---|---|---|---|---|
| Teleflex | Arrow UltraFlex 7.5 IAB Catheters | 7.5, 8 | 30, 40, 50 | 0.027 | 8, 8.5 | 60.5, 66 | 0.025 | Yes | – | – |
| Teleflex | Arrow Ultra 8 Fluid-Filled IAB Catheters | 8 | 30, 40 | 0.027 | 8 | 60.5, 66 | 0.025 | – | – | No |
| Teleflex | Arrow Ultra 8 FiberOptix IAB Catheters | 8 | 30, 40, 50 | 0.027 | 8, 8.5 | 60.5, 66, | 0.025 | – | – | Yes |
| Teleflex | Arrow Rediguard IAB Catheters | 7, 8 | 30, 40, 50 | 0.027 | 7, 8, 8.5 | 60.5, 66 | 0.025 | – | – | No |
| Teleflex | Arrow AC3 Optimus IABP | 7, 7.5, 8 | 30, 40, 50 | 0.027 | 8, 8.5 | 60.5, 66, 68.1 | 0.025 | – | – | Yes |
Other Devices / Snares
View Chart| Company Name | Product Name | Catheter Size/Length (F/cm) | Working Diameters (mm) | Snare Length (cm) | Snare Type |
|---|---|---|---|---|---|
| Teleflex | Expro Elite Snare | 0.035-inch compatible/150 length | 5, 10, 15, 25, 35 | 150 | Single-helical loop |
| Teleflex | Micro Elite Snare | 0.014-inch compatible/180 length | 2, 4, 7 | 180 | Single-helical loop |
| Teleflex | Sympro Elite Snare | 0.035-inch compatible/150 | 5, 10, 15, 25, 35 | 150 | 90° loop |
Other Devices / Thrombus Aspiration Devices
View Chart| Company Name | Product Name | Type | Maximum Tip Diameter (mm) | Minimum Guide Catheter Size (F) | Catheter Length (cm) |
|---|---|---|---|---|---|
| Teleflex | Pronto .035 Extraction Catheter | Large-vessel thrombus aspiration catheter; full-length braiding; patented Silva tip | 3.25 | 10 (sheath) | 115 |
| Teleflex | Pronto LP 5 F Extraction Catheter | Low-profile arterial embolectomy; hydrophilic coating; patented Silva tip; delivery stylet; 5-F guide catheter compatibility | 1.35 | 5 | 138 |
| Teleflex | Pronto LP Extraction Catheter | Low-profile arterial embolectomy; hydrophilic coating; patented Silva tip; round, braided shaft and stylet | 1.35 | 6 | 140 |
| Teleflex | Pronto V3 Extraction Catheter | Arterial embolectomy; hydrophilic coating; patented Silva tip; full-length braided shaft; maximized extraction lumen and force | 1.65 | 6 | 140 |
| Teleflex | Pronto V4 Extraction Catheter | Arterial embolectomy; embedded longitudinal wire; hydrophilic coating; patented Silva tip; maximized extraction lumen and force | 1.64–2.2 | 6, 7, 8 | 138 |
Stents / Covered Stents
View Chart| Company Name | Product Name | Cover Material | Stent Material/Design | Guide Catheter Compatibility (F) | Stent Diameter (mm) | Stent Length (mm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|
| Teleflex | PK Papyrus | Polyurethane | Cobalt chromium, single-stent design | 5, 6 | 2.5, 3, 3.5, 4, 4.5, 5 | 15, 20, 26 | Indicated for the treatment of acute perforations of native coronary arteries and coronary bypass grafts in vessels 2.5 to 5 mm in diameter |
Other Devices / Y-Connector/Hemostatic Valves
View Chart| Company Name | Product Name | Main Branch ID (F) | Pressure Rating (psi) | Connector Length (mm) | Bleedback Control Valve (Yes/No) | Lockable Bleedback Control Valve (Yes/No) | Rotating Valve (Yes/No) | Valve Rotations (Full Open to Full Close) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| Teleflex | Guardian II | 8 | 600 | 93 | Yes | No | Yes | 1.5 | With and without audible cue; independent wire manipulation through the valve |
More Categories: