View Chart| Company Name | Product Name | Nominal Pressure (atm) | Rated Burst Pressure (atm) | Guidewire Compatibility (inch) | Shaft Length (cm) | Sheath Compatibility (F) | Balloon Diameters (mm) | Balloon Lengths (mm) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| Teleflex | Pantera Pro | 7 | 14 | 0.014 | 140 | 5 | 1.25, 1.5, 2, 2.5, 3, 3.5, 4 | 6, 10, 15, 20, 25, 30 | Balloon and tip coating: 1.25–2 mm hydrophilic; 2.5–4 mm hydrophobic |
| Teleflex | Pantera Leo | 14 | 18–20 | 0.014 | 145 | 5 | 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 | 8, 12, 15, 20, 30 | Noncompliant balloon |
| Teleflex | Ringer Perfusion Balloon Catheter | – | – | 0.014 | – | – | – | – | – |
Advertisement
Advertisement
Balloons / Specialty Balloons
View Chart| Company Name | Product Name | Nominal Pressure (atm) | Rated Burst Pressure (atm) | Guidewire Compatibility (inch) | Size (F) | Sheath Compatibility (F) | Shaft Length (cm) | Balloon Diameters (mm) | Balloon Lengths (cm) |
|---|---|---|---|---|---|---|---|---|---|
| Teleflex | Passeo-35 | – | – | 0.035 | – | – | – | – | – |
| Teleflex | Passeo-18 | 6 | 12–15 | 0.018 | – | – | 20–200 | 2–7 | – |
| Teleflex | Passeo-14 | 7 | 14 | 0.014 | – | – | 20–220 | 1.5–4 | – |
| Teleflex | Pantera Lux | 7 | 12–13 | 0.014 | – | – | 140 | 2–4 | – |
Catheters / Angiographic Catheters
View Chart| Company Name | Product Name | Type (Braided/Nonbraided) | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Radiopaque Tip (Yes/No) | Variety of Selective Shapes |
|---|---|---|---|---|---|---|---|
| Teleflex | Arrow Balloon Wedge-Pressure | Nonbraided | 4, 5, 6, 7, 8 | 60, 90, 110 | 0.021–0.038 | No | Single- and double-lumen catheters; selection of inflated balloon diameters from 6 to 12 mm |
| Teleflex | Arrow Berman Catheters | Nonbraided | 4, 5, 6, 7, 8 | 50, 60, 70, 80, 90, 110 | 0.021–0.038 | No | Standard Berman catheter is indicated for pulmonary angiography, balloon occlusion femoral angiography (BOFA), and right heart pressure measurements; reverse Berman catheter is indicated for balloon occlusion pulmonary angiography (BOPA) |
| Teleflex | Arrow Thermodilution (Four Lumen and Five Lumen with Infusion) | Nonbraided | 5, 6, 7, 7.5 | 80, 110 | 0.021–0.038 | No | Four and five lumen catheters |
| Teleflex | Langston Dual Lumen Catheters | Braided | 6, 7 | 102, 110, 125 | – | Yes, plus five markerbands on one version | 145° pigtail and multipurpose with inner and outer lumen side holes |
Catheters / Microcatheters
View Chart| Company Name | Product Name | Type of Catheter Construction | Proximal Size (F) | Middle Size (F) | Distal Size (F) | Catheter Working Length (cm) | Catheter Endhole ID (inch) | Recommended Guidewire Size (inch) | Radiopaque Tip (Yes/No) | Hydrophilic Coating (Yes/No) |
|---|---|---|---|---|---|---|---|---|---|---|
| Teleflex | Turnpike Catheter | Hybrid multilayer: dual bidirectional coils with inner braid | 2.9 | 2.6 | 1.6 | 135, 150 | 0.0165 | 0.014 | Yes, tungsten-loaded tip | Yes |
| Teleflex | SuperCross Microcatheter OTW - 0.014 Angled Tips: 45°, 90°, 120°, and 90° Extended Tip | Dual coil design, platinum/tungsten coil tip | 3.2 | – | 2.4 | 130, 150 | 0.017 | 0.014 | Yes, platinum/tungsten coil tip | Yes |
| Teleflex | Twin-Pass Torque Dual Access Catheter | Dual-lumen catheter | 3 | 3.5 X 3.5 (dual-lumen OD) | 2.1 | 135 | 0.017 | 0.014 (RX and OTW) | Yes, two markerbands | Yes |
| Teleflex | SuperCross Microcatheter OTW - 0.014 Straight and Flexible Tip | Braided | 2.5 | – | 1.8 | 130, 150 | 0.017 | 0.014 | Yes, one markerband | Yes |
| Teleflex | Turnpike Gold Catheter | Hybrid multilayer: dual bidirectional coils with inner braid and external nylon spiral coil; incorporates a metal, threaded, gold-plated tip for enhanced rotational advancement | 2.9 | 2.9 | 2.1 | 135, 150 | 0.0165 | 0.014 | Yes, gold-plated tip | Yes |
| Teleflex | Turnpike LP Catheter | Hybrid multilayer: dual bidirectional coils with inner braid | 2.9 | 2.2 | 1.6 | 135, 150 | 0.0165 | 0.014 | Yes, tungsten-loaded tip | Yes |
| Teleflex | Turnpike Spiral Catheter | Hybrid multilayer: dual bidirectional coils with inner braid and external nylon spiral coil | 2.9 | 2.9 | 1.6 | 135, 150 | 0.0165 | 0.014 | Yes, tungsten-loaded tip | Yes |
| Teleflex | Twin-Pass Dual Access Catheter | Dual-lumen catheter | 3 | 3.4 X 2.7 (dual-lumen OD) | 2 | 135 | 0.017 | 0.014 (RX and OTW) | Yes, two markerbands | Yes |
Catheters / Specialty Catheters
View Chart| Company Name | Product Name | Catheter Size (F) | Working Length (cm) | Minimum Guiding Catheter ID (inch) | Comments |
|---|---|---|---|---|---|
| Teleflex | GuideLiner Coast Catheter | 5.5, 6, 7, 8 | 150 | 0.066, 0.070, 0.078, 0.088 | – |
| Teleflex | Twin-Pass Torque Dual Access Catheter | 3.5 X 3.5 | 135 | 0.014 (RX and OTW) | Access or delivery while maintaining wire position |
| Teleflex | Twin-Pass Dual Access Catheter | 3.4 X 2.7 (dual-lumen OD) | 135 | ≥ 0.056 (≥ 5 F) | Dual-lumen catheter with two independent 0.014-inch lumens; for guidewire access, guidewire support, and/or the delivery of contrast or medication |
| Teleflex | Turnpike LP Catheter | Distal: 1.6 (tip), 2.2 (shaft); proximal: 2.9 | 135, 150 | 0.056 (≥ 5 F) | Low profile with greater tip and distal shaft flexibility for advancement through extreme tortuosity |
| Teleflex | GuideLiner V3 Catheter | 5, 5.5, 6, 7, 8 | 150 | ≥ 0.056 (5 F); ≥ 0.066, ≥ 0.070 (6F); ≥ 0.078 (7 F); ≥ 0.088 (8 F) | Half-pipe design for seamless collar transition; this rapid-exchange, coaxial mother-and-child guide extension is delivered through standard guide catheters, resulting in an ID approximately one F size smaller than the guide catheter; used to access discrete regions of the coronary and/or peripheral vasculature and to facilitate placement of interventional devices |
| Teleflex | SuperCross Microcatheter OTW - 0.014 Angled Tips: 45°, 90°, 120°, and 90° Extended Tip | Distal: 2.4; proximal: 3.2 | 130, 150 | 0.045 | Low-profile, hydrophilic-coated, OTW microcatheter is available in multiple tip angle options (45°, 90°, 120°, 90° extended tip) with dual coil design for good torque response and delivery into branched anatomy |
| Teleflex | SuperCross Microcatheter OTW - 0.014 Straight and Flexible Tip | Distal: 1.8; proximal: 2.5 | 130, 150 | 0.035 | Low-profile, hydrophilic-coated, braided OTW microcatheter with straight tip and flexible tip options provides support when navigating tortuous anatomy and bifurcated vessels |
| Teleflex | TrapLiner Catheter | 6, 7, 8 | 150 | 0.070 (6 F), 0.078 (7 F), 0.088 (8 F) | Guide extension catheter with trapping capabilities |
| Teleflex | Turnpike Catheter | Distal: 1.6 (tip), 2.6 (shaft); proximal: 2.9 | 135, 150 | ≥ 0.056 (≥ 5 F) | Unique, multilayer shaft design and soft polymer tip that provide superior torque, flexibility, and tracking over a 0.014-inch guidewire for complex coronary and peripheral interventions |
| Teleflex | Turnpike Spiral Catheter | Distal 1.6 (tip), 2.9 (shaft); proximal: 2.9 | 135, 150 | ≥ 0.056 (≥ 5 F) | Hybrid multilayer: dual bidirectional coils with inner braid; soft polymer tip; incorporates a nylon outer coil on the distal 2 cm of the catheter for additional rotational advancement |
| Teleflex | Turnpike Gold Catheter | Distal: 2.1 (tip), 2.9 (shaft); proximal: 2.9 | 135, 150 | ≥ 0.056 (≥ 5 F) | Hybrid multilayer: dual bidirectional coils with inner braid and external nylon spiral coil; incorporates a metal, threaded, gold-plated tip for enhanced rotational advancement |
Sheaths / Special Access Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip (Yes/No) | Type of Special Access |
|---|---|---|---|---|---|---|---|
| Teleflex | VSI Micro-Introducer Kits | 4, 5 | 10, 15, 30 | 0.018–0.038 compatible | Curved or straight | No | Percutaneous introduction of catheter or guidewire into vascular system following a small-gauge needle stick |
| Teleflex | OptiSeal Valved Peelable Introducer | 6–12 | 13, 25 | 0.035 | Straight | No | Pacing lead implants, PICC lines, and central venous catheter implants |
| Teleflex | Super Arrow-Flex Carotid Access Sheath Introducer Set | 7 | 90 | – | Straight | Yes | Carotid |
| Teleflex | Super Arrow-Flex Renal Access Sheath Introducer Sets | 6, 7 | 45 | 0.035–0.038 | Curved, 90° | Yes | Renal |
| Teleflex | Super Arrow-Flex Transseptal Access Sheath Introducer Set | 8 | 61 | – | Straight | Yes | Transseptal |
Sheaths / Standard Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip (Yes/No) |
|---|---|---|---|---|---|---|
| Teleflex | Fortress | 4–8 | 45, 65, 60 | 0.035 | Pre-curved and straight | Yes |
| Teleflex | Fortress | 4–8 | 45, 65, 90 | 0.035 | – | – |
Stents / Bioabsorbable Polymer Drug-Eluting Stents
View Chart| Company Name | Product Name | Drug Delivered | Material Used | Polymer Type | Maximum Guidewire Size (inch) | Introducer Size (F) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|---|---|---|
| Teleflex | Orsiro Mission | Sirolimus | Cobalt chromium | PLLA | 0.014 | 5 (diameter: 2.25-4 mm), 6 (diameter: 4.5-5 mm) | 2.25, 2.5, 2.75, 3, 3.5, 4, 4.5, 5 | 9, 13, 15, 18, 22, 26, 30, 35, 40 | 140 | Indicated for improving coronary luminal diameter in patients, including those with diabetes mellitus, with symptomatic heart disease, stable angina, unstable angina, non–ST-segment elevation myocardial infarction or documented silent ischemia due to atherosclerotic lesions in the native coronary arteries with a reference vessel diameter of 2.25 to 4 mm and a lesion length of ≤ 36 mm |
Stents / Coronary Balloon-Expandable Stents
View Chart| Company Name | Product Name | Material Used | Maximum Guidewire Size (inch) | Introducer Size (F) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | Comments |
|---|---|---|---|---|---|---|---|---|
| Teleflex | Pulsar-18 T3 | – | 0.018 | 4 | 4–7 | 20–200 | 90, 135 | – |
| Teleflex | Astron | – | 0.035 | 6 | 7–10 | 30–80 | 72, 130 | – |
Wires / Interventional CTO/Specialty Wires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type | Coating Type (Hydrophilic or Hydrophobic) | Comments |
|---|---|---|---|---|---|---|---|
| Teleflex | Raider Guidewire | Specialty wire | 0.014 | 200, 300 | Stainless steel core-to-tip; 10-cm platinum coil; straight tip | PTFE (proximal); hydrophilic (distal) | Black polymer jacket covering the coil tip |
| Teleflex | R350 Guidewire | Externalization wire | 0.013 | 350 | Nitinol core-to-tip; gold-plated tungsten coil; straight tip | PTFE (proximal: 150 cm); hydrophilic (distal: 200 cm) | – |
Wires / Interventional Workhorse Wires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type | Coating Type (Hydrophilic or Hydrophobic) | Comments |
|---|---|---|---|---|---|---|---|
| Teleflex | Spectre Guidewire | Workhorse wire | 0.014 | 190, 300 | Stainless steel-to-nitinol core-to-tip; straight tip | PTFE (proximal); hydrophilic (distal) | – |
Other Devices / Assisted Compression Devices
View Chart| Company Name | Product Name | Type | Puncture Size (F) | Maximum Wire Compatibility | Comments |
|---|---|---|---|---|---|
| Teleflex | QuikClot Radial Hemostatic Bandage | Topical hemostatic bandage for radial punctures | All, including up to 12 | – | Soft, white hydrophilic roll dressing impregnated with kaolin; does not contain animal or human proteins; packaged with a unique direct pressure dressing to hold the bandage in place and provide compression |
| Teleflex | QuikClot Interventional Hemostatic Bandage | Topical hemostatic bandage | All, including up to 12 | – | A kaolin-based hemostatic pad and 3M Tegaderm adhesive bandage applied topically as an adjunct to manual compression and indicated for the local management and control of surface bleeding from vascular access sites; double packaged in a blister package and foil pouch for aseptic use |
| Teleflex | Vasc Band Hemostat | Hemostasis device | All | – | Inflatable hemostasis device consisting of a soft, adjustable plastic strap, compression balloon, and proprietary inflation syringe |
| Teleflex | D-Stat Rad-Band Topical Hemostat | Mechanical compression device with thrombin that is designed to facilitate hemostasis of radial punctures | All | – | Adjustable radial compression band that consists of a nonwoven pad containing thrombin, an adjustable strap, and attached foam comfort pads |
| Teleflex | Accumed Wrist Positioning Splint | Radial positioning and stabilization device | – | – | Single-use splint that promotes optimal wrist angle for arterial access and minimizes unwanted hand and arm movement before, during, and after a transradial procedure |
Other Devices / Closure Devices
View Chart| Company Name | Product Name | Type | Puncture Size (F) | Maximum Wire Compatibility (inch) | US FDA Indicated Use | Comments |
|---|---|---|---|---|---|---|
| Teleflex | Manta Vascular Closure Device | Bioresorbable implant | Following the use of 10–20 F device or sheaths (12–25 F OD) | 0.035 | Indicated for closure of femoral artery access sites while reducing time to hemostasis following the use of 10–20-F devices or sheaths (12–25-F OD) in endovascular catheterization procedures | Designed specifically for closure of large bore femoral artery access sites; easy positioning without the need for preclosure; simple deployment with help from auditory and visual cues and a reliable closure using a single device |
Other Devices / Snares
View Chart| Company Name | Product Name | Catheter Size/Length (F/cm) | Working Diameters (mm) | Snare Length (cm) | Snare Type |
|---|---|---|---|---|---|
| Teleflex | Micro Elite Snare | 0.014-inch compatible/180 length | 2, 4, 7 | 180 | Single-helical loop |
Stents / Covered Stents
View Chart| Company Name | Product Name | Cover Material | Stent Material/Design | Guide Catheter Compatibility (F) | Stent Diameter (mm) | Stent Length (mm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|
| Teleflex | PK Papyrus | Polyurethane | Cobalt chromium, single-stent design | 5, 6 | 2.5, 3, 3.5, 4, 4.5, 5 | 15, 20, 26 | Indicated for the treatment of acute perforations of native coronary arteries and coronary bypass grafts in vessels 2.5 to 5 mm in diameter |
Other Devices / Y-Connector/Hemostatic Valves
View Chart| Company Name | Product Name | Main Branch ID (F) | Pressure Rating (psi) | Connector Length (mm) | Bleedback Control Valve (Yes/No) | Lockable Bleedback Control Valve (Yes/No) | Rotating Valve (Yes/No) | Valve Rotations (Full Open to Full Close) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| Teleflex | Guardian II | 8 | 600 | 93 | Yes | No | Yes | 1.5 | With and without audible cue; independent wire manipulation through the valve |
Balloons / Drug-Coated Balloons
View Chart| Company Name | Product Name | Drug Type | Drug Concentration (µg/mm2) | Excipient Type | Guidewire Compatibility (inch) | Shaft Length (cm) | Sheath Compatibility (F) | Balloon Diameters (mm) | Balloon Lengths (cm) |
|---|---|---|---|---|---|---|---|---|---|
| Teleflex | Pantera Lux | Paclitaxel | 3.0 | BTHC | 0.014 | 140 | 5 | 2.0–4.0 | 10–30 |