Philips |
AngioSculpt RX PTCA Scoring Balloon Catheter
|
8 |
20 |
0.014 |
6 |
6 |
137 |
2, 2.5, 3, 3.5 |
6, 10, 15 |
|
B. Braun Interventional Systems, Inc. |
BIB Catheter
|
1–3.5 |
2–7 |
0.035 |
8, 9, 11 |
8, 9, 10, 11, 16 |
110 |
12, 14, 15, 16, 18, 20, 22, 24, 26, 28, 30 |
2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6, 6.5 |
|
TriReme Medical LLC |
Chocolate PTCA Balloon Catheter
|
10 |
16 |
0.014 |
5 (2–2.5 mm), 6 (3–3.5 mm) |
5 (2–2.5 mm), 6 (3–3.5 mm) |
140 |
2, 2.5, 3, 3.5 |
1, 1.5, 2 |
|
B. Braun Interventional Systems, Inc. |
Corodyn A Angiographic Balloon Flotation Catheter
|
Nominal inflated diameter: 8, 10, 12 mm |
Max injection pressure: 650, 700, 900 PSI |
– |
5, 6, 7 |
– |
50, 60, 80, 90, 110 |
8, 10, 12 |
– |
|
B. Braun Interventional Systems, Inc. |
Corodyn P1 Monitoring Wedge Pressure Balloon Flotation Catheter
|
Nominal inflated diameter: 8, 10, 12 mm |
Max. balloon inflation capacity: 0.75, 1.25, 1.5 mL |
0.025, 0.038 |
5, 6, 7 |
– |
60, 110 |
8, 10, 12 |
– |
|
Cordis |
Flash Mini Ostial System
|
9 (3–4.5 mm) |
20 (3–4.5 mm) |
0.014 |
6 (3–4.5 mm) |
5 (3–4.5 mm) |
135 |
Distal: 3, 3.5, 4, 4.5; proximal: 9 |
Distal: 8; proximal: 0.9 |
|
Cordis |
Flash Ostial System
|
8 (5–7 mm), 9 (4, 4.5 mm) |
12 (5–7 mm), 20 (4–4.5 mm) |
0.014 (4–7 mm), 0.035 (7 mm) |
6 (4–6 mm), 7 (7 mm), 8 (7 mm, 0.035 inch) |
5 (4–6 mm), 6 (7 mm) |
135 |
Distal: 4, 4.5, 5, 6, 7; proximal: 12.6 |
Distal: 12, 17; proximal: 1.3 |
|
B. Braun Interventional Systems, Inc. |
Mini Ghost PTA Catheter
|
Up to 10 |
Up to 20 |
0.018 |
3.5 |
4 |
40, 80, 120, 150 |
2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6 |
1, 2, 3, 4, 6, 8, 10 |
|
B. Braun Interventional Systems, Inc. |
PTS Sizing Balloon
|
Up to 0.75 |
Up to 1.5 |
0.035 |
– |
8, 9 |
80 |
20, 25, 30, 40 |
3, 4, 5 |
|
B. Braun Interventional Systems, Inc. |
PTS-X Sizing Balloon
|
Up to 0.75 |
Up to 1.5 |
0.035 |
– |
8, 9 |
80, 110 |
20, 25, 30, 35, 40 |
3, 4, 5 |
|
Abbott (manufactured by OrbusNeich) |
Scoreflex NC Scoring PTCA Catheter
|
12 |
20 |
0.014 |
– |
5 (diameter, 1.75–3.5); 6 (diameter, 0.40) |
140 |
1.75–4 |
10–20 |
|
Boston Scientific Corporation |
Wolverine Monorail Cutting Balloon Dilation Device
|
6 |
12 |
0.014 (guidewire compatible) |
2.7 |
6 |
MR: 142; OTW: 143 |
2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4 |
6, 10, 15 |
|
Boston Scientific Corporation |
Wolverine Over-the-Wire Cutting Balloon Dilation Device
|
6 |
12 |
0.014 (guidewire compatible) |
2.7 |
6 |
143 |
2, 2.5, 3, 3.5, 4 |
6, 10, 15 |
|
B. Braun Interventional Systems, Inc. |
Z-5 Atrioseptostomy Catheter
|
– |
1, 2 mL (maximum inflation volume) |
0.014, 0.021 |
4, 5 |
5, 6 |
50 |
9.5, 13.5 |
0.95, 1.35 |
|
B. Braun Interventional Systems, Inc. |
Z-6 Atrioseptostomy Catheter
|
– |
1, 2 mL (maximum inflation volume) |
0.021 |
5 |
6 |
50 |
9.5, 13.5 |
0.95, 1.35 |