Catheters / Microcatheters

View Chart
Company Name Product Name Type of Catheter Construction Proximal Size (F) Middle Size (F) Distal Size (F) Catheter Working Length (cm) Catheter Endhole ID (inch) Recommended Guidewire Size (inch) Radiopaque Tip (Yes/No) Hydrophilic Coating (Yes/No)
Cook Medical Cantata 2.8 Braided stainless steel, PTFE, Pebax 2.8 2.8 2.8 100, 110, 135, 150 0.025 0.021 (maximum) Yes Yes
Cook Medical Cantata 2.9 Braided stainless steel, PTFE, Pebax 2.9 2.9 2.9 100, 110, 135, 150 0.027 (0.69 mm) 0.025 (maximum) Yes Yes
Cook Medical Cantata 2.5 Braided stainless steel, PTFE, Pebax 2.5 2.5 2.5 100, 110, 135, 150 0.021 0.018 (maximum) Yes Yes

Advertisement

Advertisement

Catheters / Specialty Catheters

View Chart
Company Name Product Name Catheter Size (F) Working Length (cm) Minimum Guiding Catheter ID (inch) Comments
Cook Medical TriForce Peripheral Crossing Set Inner catheter: 4, outer sheath: 5, tapering to 4 (0.035-inch wire) 65, 100 0.052 Coaxial peripheral crossing set; both inner catheter and outer sheath are hydrophilically coated; inner catheter is braided with radiopaque tip; outer sheath is coil reinforced to provide exceptional tracking through tortuous anatomy; a tungsten-loaded tip on the outer sheath aids pushability and radiopacity; outer sheath is tapered down to inner catheter to provide additional support, strength, and pushability across challenging lesions

Sheaths / Special Access Sheaths

View Chart
Company Name Product Name Size (F) Length (cm) Guidewire Compatibility (inch) Curved or Straight Radiopaque Tip (Yes/No) Type of Special Access
Cook Medical Check-Flo: Extra Large 20–24 25, 40, 65 0.038 Straight No Large device/stent graft
Cook Medical Flexor Radial Hydrophilic Introducer Access Set 4, 5, 6, 7 7, 13, 23 0.018 (nitinol with palladium) Straight No Radial artery access
Cook Medical Keller-Timmermans 18–24 65, 85 0.038 Straight, curved No Large device/stent graft
Cook Medical Micropuncture Pedal Introducer Access Set 2.9 7 0.018 X 40 cm (nitinol with platinum tip) Angled No Pedal access
Cook Medical Performer: Hausdorf-Lock 8–12 75 0.038 Curved Yes Transseptal access
Cook Medical Performer: Micropuncture 4–7 13 0.018 Straight No Hybrid introducer sheath and micropuncture set to expedite standard sheath access
Cook Medical Performer: Mullins 4–16 48, 63, 75, 85 0.038 Curved Yes Transseptal access
Cook Medical Performer: Radial 6 7, 23 0.018 Straight No Radial artery access

Sheaths / Standard Sheaths

View Chart
Company Name Product Name Size (F) Length (cm) Guidewire Compatibility (inch) Curved or Straight Radiopaque Tip (Yes/No)
Cook Medical Performer: Small Valve 4–8 5, 5.5, 7, 13, 25, 30, 35, 45 0.035, 0.038 Straight With or without

Wires / Interventional Support Wires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type Coating Type (Hydrophilic or Hydrophobic) Comments
Cook Medical Amplatz Extra Stiff With Apex Curve Fixed core 0.035 260 Double curved (8 mm primary, 2 mm secondary curve) PTFE coating Contains a unique double/spiral curve; intended to facilitate the introduction and placement of interventional devices within the chambers of the heart, including those used within transcatheter aortic valve procedures

Other Devices / Biopsy Forceps

View Chart
Company Name Product Name Shaft OD (F) Length (cm) Approach Shapeable Tip (Yes/No)
Cook Medical Transluminal Biliary Biopsy Forceps Set 7 (5.2 forceps size) 30 (60-cm forceps length) Percutaneous transluminal No

Other Devices / CTO Crossing Devices

View Chart
Company Name Product Name Catheter Tip OD (inch) Wire Size (inch) Working Length (cm) Minimum Guiding Catheter ID (F) Comments
Cook Medical TriForce Peripheral Crossing Set Inner catheter: 4, outer sheath: 5, tapering to 4 (0.035-inch wire) 0.035 65, 100 0.052 inch Coaxial peripheral crossing set; both inner catheter and outer sheath are hydrophilically coated; inner catheter is braided with radiopaque tip; outer sheath is coil reinforced to provide exceptional tracking through tortuous anatomy; a tungsten-loaded tip on the outer sheath aids pushability and radiopacity; outer sheath is tapered down to inner catheter to provide additional support, strength, and pushability across challenging lesions

Other Devices / Mechanical Thrombectomy/Thrombolysis

View Chart
Company Name Product Name Sheath Compatibility (F) Guidewire Compatibility (inch) Working Length (cm) Mode of Operation US FDA Indicated Use
Cook Medical Multi-Sideport Catheter Infusion Set 5 0.035 65, 100, 130 Manual administration of infusate Intended to administer infusions of various therapeutic solutions and contrast media into the peripheral vasculature (refer to manufacturer’s package insert for complete prescribing and dosing information)

Other Devices / Snares

View Chart
Company Name Product Name Catheter Size/Length (F/cm) Working Diameters (mm) Snare Length (cm) Snare Type
Cook Medical CloverSnare 4-Loop Vascular Retriever 6/90, 8/85, 10/80 32 90 Four-loop nitinol snare with tantalum core coaxial sheath system with radiopaque markers at each distal tip
Cook Medical Curry Intravascular Retriever 6.3/100, 8/100 0.018, 0.021 inch 150 Folds at midpoint and forms a loop when passed through the catheter; supplied sterile in peel-open packages; intended for one-time use
Cook Medical Dotter Intravascular Retriever 8/95 30-mm basket 7-cm basket Helical loop basket is loaded into the hub of the catheter and expands upon emergence from the distal tip; supplied sterile in peel-open packages; intended for one-time use
Cook Medical Günther Tulip Vena Cava Filter Retrieval Set 6.3/80 20-mm snare loop – The GTRS jugular approach consists of a retrieval loop system with a braided platinum wire loop, a coaxial retrieval sheath system, an entry needle, a wire guide, and a dilator; a radiopaque band provided on the outer sheath identifies precise location of the distal tip of the sheath for positioning accuracy
Cook Medical Indy OTW Snare 8/55, 8/100 40-mm basket 55/100-cm catheter Four-loop petal radiopaque nitinol

Other Devices / Transseptal Needles

View Chart
Company Name Product Name Needle Length (cm) Proximal Gauge Size Distal Gauge Size Curve Type Comments
Cook Medical Transseptal Needle 56 19 22 – Used for transseptal left heart access in both diagnostic and interventional procedures
Cook Medical Transseptal Needle 71 18 21 – Used for transseptal left heart access in both diagnostic and interventional procedures

More Categories:

Balloons Catheters Sheaths Stents Structural Heart Valves Wires Other Devices View All

Advertisement

Latest News


April 21, 2026

TECTONIC IDE Trial of Abbott’s Coronary IVL Device Completes Enrollment 

April 21, 2026

Conavi’s IVUS-OCT System for Intravascular Imaging Cleared by FDA

April 20, 2026

KingstronBio Announces First Implant of ProStyle M Transcatheter Mitral Valve System in Confirmatory Study

Most Read Articles


Advances in Wiring and Balloon Technology for Complex PCI

With Raghav Gattani, MD, and Lindsey Cilia, MD, FACC, FSCAI

For Suspected Coronary Calcium Nodules, What Is Your Step-by-Step PCI Strategy?

With Shrilla Banerjee, MD, FRCP, FESC; Jimmy L. Kerrigan, MD, FSCAI, FACC; and Aditya S. Bharadwaj, MD, FACC, FSCAI

New PCI Directions

By Louis Verreault-Julien, MD

Back to Top
Coding CTO DES Hypertension Imaging Modalities PCI Pharmacology Radial Regulatory Structural Disease Valvular Interventions
Centers

Coding CTO DES Hypertension Imaging Modalities PCI Pharmacology Radial Regulatory Structural Disease Valvular Interventions

News• Current Issue• Archive• Device Guides• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Cardiac Interventions Today (ISSN 2572-5955 print and ISSN 2572-5963 online) is a publication dedicated to providing coverage of the latest developments in technology, techniques, clinical studies, and regulatory and reimbursement issues in the field of coronary and cardiac interventions.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. BlueSky-Circle
Endovascular Today
CIT-Logo-Color Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button