AndraTec GmbH Germany |
AltoSa-SFT Tacking Balloon
|
2 |
2 |
0.035 |
10.5 |
12 |
65, 110, 130 |
45 |
4 |
|
AndraTec GmbH Germany |
Altosa-T18
|
4 |
8 |
0.018, 0.035 |
3.5 |
4, 5, 6 |
80 |
4–18 |
2, 3, 4, 6 |
|
AndraTec GmbH Germany |
AltoSa-XL PTA Balloon
|
3 |
10 |
0.035 |
6.5, 7, 8 |
8–12 |
110 |
12–30 |
2, 3, 4, 5, 6 |
|
AndraTec GmbH Germany |
AltoSa-XL-Gemini Dual Balloon Technology
|
3 |
10 |
0.035 |
8 |
8–16 |
110 |
14–30 |
3, 4, 5, 6, 10 |
|
Philips |
AngioSculpt RX PTCA Scoring Balloon Catheter
|
8 |
Up to 20 |
0.014 |
6 |
6 |
137 |
2, 2.5, 3, 3.5 |
6, 10, 15 |
|
B. Braun Melsungen AG |
BIB Catheter
|
1.5, 2, 2.5, 3, 3.5 |
3, 4, 5, 6, 7 |
0.035 |
8, 9 |
8, 9, 10, 11 |
110 |
12, 14, 15, 16, 18, 20, 22, 24 |
2.5, 3, 3.5, 4, 4.5, 5, 5.5 |
|
TriReme Medical LLC |
Chocolate PTCA Balloon Catheter
|
10 |
16 |
0.014 |
5 (2–2.5 mm), 6 (3–3.5 mm) |
5 (2–2.5 mm), 6 (3–3.5 mm) |
140 |
2, 2.5, 3, 3.5 |
1, 1.5, 2 |
|
B. Braun Melsungen AG |
Impact
|
2–6 |
4–10 |
0.035 |
6–9 |
8–14 |
75, 120 |
12, 14, 16, 18, 20, 22, 25 |
2, 4 |
|
Concept Medical |
MagicTouch ED
|
8 bar |
14 bar |
0.014 |
6 |
– |
– |
1.50, 2, 2.25, 2.50, 2.75, 3, 3.50, 4 |
1, 1.5, 2, 2.5, 3, 3.5, 4 |
|
B. Braun Melsungen AG |
Mini Ghost
|
6–10 |
12–20 |
0.018 |
3.5 |
4 |
40, 80 |
2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6 |
1, 2, 3, 4, 6, 8, 10 |
|
iVascular |
Naviscore
|
8 |
20 |
0.014 |
6 |
6 |
142 |
1.5, 2, 2.5, 3, 3.5 |
6, 8, 10, 12, 15 |
|
B. Braun Melsungen AG |
NSE Alpha
|
6 |
14 |
0.014 |
– |
6 (guiding catheter compatibility) |
143 |
2, 2.25, 2.5, 2.75, 3, 3.5, 4 |
1.3 |
|
B. Braun Melsungen AG |
PTS Sizing Balloon
|
0.25–0.75 |
Up to 1.5 |
0.035 |
8 |
8, 9 |
80 |
20, 25, 30, 40 |
3, 4, 5 |
|
B. Braun Melsungen AG |
PTS-X Sizing Balloon
|
0.25–1.25 |
Up to 2.5 |
0.035 |
6, 8 |
6, 8, 9 |
80 |
10, 12, 15, 20, 25, 30, 35, 40 |
1, 2, 3, 4, 5, 6 |
|
B. Braun Melsungen AG |
SeQuent NEO NC
|
12 |
20 |
0.014 |
– |
5 (guiding catheter compatibility) |
140 |
2, 2.25, 2.5, 2.75, 3, 3.5, 4, 4.5 |
0.8, 1, 1.2, 1.5, 2, 3 |
|
BrosMed Medical |
Wedge NC Scoring PTCA Balloon Dilatation Catheter
|
12 |
22 |
0.014 |
2 (proximal shaft OD), 3 (distal shaft OD) |
5 |
140 |
2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4 |
0.6, 0.8, 1, 1.2, 1.5, 1.8, 2, 2.3, 2.5, 3 |
|
Boston Scientific Corporation |
Wolverine Cutting Balloon Dilation Device
|
6 |
12 |
0.014 (guidewire compatible) |
2.7 |
6 |
142 (monorail) |
2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4 |
6, 10, 15 |
|
B. Braun Melsungen AG |
Z-5 Atrioseptostomy Catheter
|
– |
1, 2 mL (maximum inflation volume) |
0.014, 0.021 |
4, 5 |
5, 6 |
50 |
9.5, 13.5 |
0.95, 1.35 |