| Compare | Company Name | Product Name | Nominal Pressure (atm) | Rated Burst Pressure (atm) | Guidewire Compatibility (inch) | Shaft Length (cm) | Sheath Compatibility (F) | Balloon Diameters (mm) | Balloon Lengths (mm) | Comments |
|---|---|---|---|---|---|---|---|---|---|---|
| Terumo Europe | Accuforce | 12 (1,216 kPa) | 20 (2,026 kPa) for 4.5, 5 mm; 22 (2,229 kPa) for 2–4 mm | Entry profile: 0.0169 (0.43 mm) | 145 | – | 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 | 6, 8, 12, 15, 20, 25, 30 | The ideal balance of high pressure and high resistance, accurate dilatation, and advanced deliverability with no compromise on procedural success; improved accuracy of dilatation even in the most challenging cases with shorter balloon shoulders; (compared to Hiryu noncompliant PTCA balloon catheter [Terumo Corporation]; data on file at Terumo Corporation; compliance comparison from benchmark test data vs various competitors) | |
| BrosMed Medical | Alveo HP CTO Balloon Dilatation Catheter | 10 | 20 | 0.014 | 140 | 5 | 0.75, 1, 1.25, 1.5, 1.75, 2 | 5, 8, 10, 12, 15, 20, 25, 30 | An ultra-low tip entry profile of 0.0156-inch | |
| Philips | AngioSculpt PTCA X Drug-Coated Scoring Balloon Catheter RX | 8 | Up to 20 | 0.014 | 137 | 6 | 2, 2.5, 3, 3.5 | 10, 15, 20 | Indicated for the treatment of significant coronary artery stenosis, including in-stent restenosis for the purpose of improving myocardial perfusion | |
| Philips | AngioSculpt RX PTCA Scoring Balloon Catheter | 8 | Up to 20 | 0.014 | 137 | 6 | 2, 2.5, 3, 3.5 | 6, 10, 15 | – | |
| Boston Scientific Corporation | Apex Monorail PTCA Dilatation Catheter | 6 | 14 | 0.014 | 143 | 5 | 1.5 (Push model), 1.5 (Flex model), 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 | 8, 12, 15, 20, 30, 40 | – | |
| Boston Scientific Corporation | Apex Over-the-Wire PTCA Dilatation Catheter | 6 | 14 | 0.014 | 140 | 6 | 1.5 (Push model), 1.5 (Flex model), 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 | 8, 12, 15, 20, 30, 40 | – | |
| BrosMed Medical | Apollo NC PTCA Balloon Dilatation Catheter | 12 | 20 (Ø, 4.5–5 mm), 22 (Ø, 2–4 mm) | 0.014 | 140 | 5/6 compatible, 6 compatible for kissing | 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 | 6, 8, 10, 12, 15, 18, 20, 22, 25, 30 | Superior high pressure performance and performance reliability | |
| BrosMed Medical | Artimes SC PTCA Balloon Dilatation Catheter | 6 | 14 | 0.014 | 140 | 5 compatible, 6 compatible for kissing | 1, 1.25, 1.5, 1.75, 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4 | 5, 8, 10, 12, 15, 20, 25, 30 | Ideal for the treatment of CTOs | |
| Boston Scientific Corporation | Emerge Monorail PTCA Dilatation Catheter | 6 | 12, 14 (depending on diameter) | 0.014 | 144 | 5 | 1.2, 1.2 (Push model), 1.5, 1.5 (Push model), 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4 | 8, 12, 15, 20, 30 | Exceptional deliverability, ultra-low tip profile | |
| Boston Scientific Corporation | Emerge Over-the-Wire PTCA Dilatation Catheter | 6 | 12, 14 (depending on diameter) | 0.014 | 143 | 5 | 1.2, 1.2 (Push model), 1.5, 1.5 (Push model), 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4 | 8, 12, 15, 20, 30 | – | |
| Medtronic | Euphora (SC) | 8 | 14 | 0.014 | 142 | Balloon diameters 1.5–4 mm are compatible within a 5-F guide catheter (MGCID: 0.056); any combination of two Euphora RX Balloon Dilatation Catheters (1.5–3.5 mm) can be used simultaneously within a 6-F guide catheter (MGCID: 0.070) | 1.5, 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4 | 6, 10, 12, 15, 20, 25, 30 | – | |
| Rontis AG | Europa Ultra | 8 | 16 | 0.014 | 140 | 5 | 2, 2.25, 2.5, 2.75, 3, 3.5, 4, 4.5, 5 | 10, 15, 20, 25, 30 | Semicompliant dilatation catheter with ABP up to 26 atm | |
| Rontis AG | Europa Ultra CTO (Rx-OTW) | 8 | 18 | 0.014 | Rx: 140, OTW: 150 | 5 (minimum) | 1, 1.25, 1.5 | 8, 12, 16, 20 (inner diameter: 1); 10, 15, 20 (inner diameter: 1.25, 1.5) | CTO dilatation catheter with inner diameter from 1 mm; ABP ≤ 28 atm; Rx-OTW | |
| Rontis AG | Europa Ultra NC | 10 | 18 (inner diameter: 2–4 mm), 20 (inner diameter: 4.5–5 mm) | 0.014 | 140 | 5 (minimum) | 2, 2.25, 2.5, 2.75, 3, 3.5, 4, 4.5, 5 | 10, 15, 20, 25, 30 | Noncompliant dilatation catheter with ABP ≤ 28 atm | |
| Alvimedica | Fluydo | 6 | 14 | 0.014 | 142 | 5 (GC compatibility) | 1.5, 2, 2.5, 3, 3.5, 4 | 10, 15, 20, 30 | – | |
| TriReme Medical LLC | Glider PTCA Balloon Catheter | 8 (2.5–3 mm), 9 (3.5 mm), 11 (1.5–2 mm) | 14 (3.5 mm), 16 (1.5–3 mm) | 0.014 | 135 | 6 | 1.5, 2, 2.5, 3, 3.5 | 4, 8, 12, 20 | – | |
| Cordis | Ikazuchi Zero PTCA balloon | 6 | 14 | 0.014 | 146 | 5 | 1, 1.2, 1.5, 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4 | 6, 8, 10, 12, 15, 20, 30 | Ultra low crossing profile (0.0157 inch for the 1-mm diameter balloon) | |
| Alvimedica | Invader CTO | 7 | 14 | 0.014 | 150 | 5 (GC compatibility) | 1.25, 1.5, 2 | 10, 15, 20, 25 | – | |
| Alvimedica | Invader PTCA | 8 | 16 | 0.014 | 144 | 5 (GC compatibility) | Double marker: 1.25, 1.5, 2, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 (CE Mark approval pending); single marker: 1.5, 2, 2.5 | 6, 10, 12, 15, 20, 25, 30, 34 (CE Mark approval pending) | – | |
| Concept Medical | MagicTouch SCB | 6 bar | 16 bar | 0.014 maximum recommended | 140 | 6 | 1.50, 2, 2.25, 2.50, 2.75, 3, 3.50, 4 | 10, 15, 20, 25, 30, 35, 40 | Magic Touch is a sirolimus drug-coated balloon catheter for treatment of the coronary arteries; intended for treating in-stent restenosis, small vessel, bifurcations lesions, and de novo lesions | |
| BrosMed Medical | Mars NC PTCA Balloon Dilatation Catheter | 12 | 22, 20 | 0.014 | 145 | 5, 6 | 2–6 | 6–30 | Outstanding noncompliance performance | |
| BrosMed Medical | Mars PTCA Balloon Dilatation Catheter | 6 | 14 | 0.014 | 145 | 5, 6 | 1–4 | 5–30 | Facilitate lower crossing profile and better crossability, flexibility, and trackability | |
| Abbott | Mini Trek OTW II Coronary Dilation Catheter | 8 | 14 | 0.014 | 145 | – | 1.2, 1.5, 2 | 6, 8, 12, 15, 20 | – | |
| Abbott | Mini Trek RX Coronary Dilation Catheter | 8 | 14 | 0.014 | 145 | – | 1.2, 1.5 | 6, 8, 12, 15, 20 | – | |
| Abbott | Mini Trek RX Coronary Dilation Catheter | 8 | 14 | 0.014 | 145 | – | 2 | 6, 8, 12, 15, 20, 25, 30 | – | |
| Meril Life Sciences Pvt. Ltd. | Mozec NC Rx PTCA Balloon Dilatation Catheter | 12 | 20 | 0.014 | 142 | 5 | 2, 2.5, 2.75, 3, 3.5, 4, 4.5 | 8, 10, 13, 15, 18, 23, 28, 30, 35, 38 | Flat compliance at high pressure; distributed by Cordis in the United States and Canada | |
| Meril Life Sciences Pvt. Ltd. | Mozec Rx PTCA Balloon Dilatation Catheter | 7 | 14, 16 (depending on diameter) | 0.014 | 142 | 5 | 1.25, 1.5, 2, 2.25, 2.5, 2.75, 3, 3.5, 4, 4.5* | 6, 9, 12, 14, 15, 17, 20, 25, 30, 33, 38, 41, 45, 49 | *14-atm RBP; distributed by Cordis in the United States and Canada | |
| Meril Life Sciences Pvt. Ltd. | Mozec Rx PTCA Balloon Dilatation Catheter | 7 | 16 | 0.014 | 142 | 5 | 1.5, 2 | 9, 12, 15 | 5-mm tip length; distributed by Cordis in the United States and Canada | |
| Boston Scientific Corporation | NC Emerge Monorail PTCA Dilatation Catheter | 12 | 18/20 | 0.014 | 143 | 5, 6 | 2, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5, 5.5, 6 | 6, 8, 12, 15, 20, 30 | – | |
| Boston Scientific Corporation | NC Emerge Over-the-Wire PTCA Dilatation Catheter | 12 | 18/20 | 0.014 | 142 | 5, 6 | 2, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5, 5.5, 6 | 6, 8, 12, 15, 20, 30 | – | |
| Medtronic | NC Euphora | 12 | 20 | 0.014 | 142 | Balloon diameters 2–4 mm are compatible with 5-F guide catheters (MGCID: 0.056); balloon diameters 4.5–5 mm are compatible with 6-F guide catheters (MGCID: 0.066) | 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 | 6, 8, 12, 15, 20, 27 | – | |
| Boston Scientific Corporation | NC Quantum Apex Monorail PTCA | 12 | 18/20 | 0.014 | 143 | 5, 6 | 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 | 6, 8, 12, 15, 20, 30 | – | |
| Boston Scientific Corporation | NC Quantum Apex Over-the-Wire PTCA | 12 | 18/20 | 0.014 | 142 | 5, 6 | 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 | 6, 8, 12, 15, 20, 30 | – | |
| Abbott | NC Trek OTW Coronary Dilatation Catheter | 12 | 18 | 0.014 | 143 | – | 1.5, 2, 2.25, 2.75, 3.25 | 6, 8, 12, 15, 20 | – | |
| Abbott | NC Trek OTW Coronary Dilatation Catheter | 12 | 18 | 0.014 | 143 | – | 2.5, 3, 3.5 | 6, 8, 12, 15, 20, 25 | – | |
| Abbott | NC Trek OTW Coronary Dilatation Catheter | 12 | 18 | 0.014 | 143 | – | 3.75, 4, 4.5, 5 | 8, 12, 15, 20 | – | |
| Abbott | NC Trek RX Coronary Dilatation Catheter | 12 | 18 | 0.014 | 143 | – | 2.5, 3, 3.5 | 6, 8, 12, 15, 20, 25 | – | |
| Abbott | NC Trek RX Coronary Dilatation Catheter | 12 | 18 | 0.014 | 143 | – | 1.5, 2, 2.25, 2.5, 3.25 | 6, 8, 12, 15, 20 | – | |
| Abbott | NC Trek RX Coronary Dilatation Catheter | 12 | 18 | 0.014 | 143 | – | 3.75, 4, 4.5, 5 | 8, 12, 15, 20 | – | |
| iVascular | NC Xperience | 12 | 18 (Ø ≥ 4.5 mm), 20 (Ø < 4.5 mm) | 0.014 | 142 | 5 (for all diameters), 6 (for kissing-balloon technique) | 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 | 6, 8, 10, 12, 15, 20, 25, 30 | Average burst pressure: 25 atm | |
| Cordis | Neon NC PTCA balloon | 12 | 22 | 0.014 | 146 | 5 | 1.5, 1.75, 2, 2.25, 2.5, 3, 3.25, 3.5, 3.75, 4, 4.25, 4.5 | 8, 10, 13, 15, 20, 30 | Japanese balloon design, ultra–low profile post-dilatation balloon | |
| Cordis | Neon PTCA balloon | 6 | 14 | 0.014 | 146 | 5 | 1, 1.2, 1.5, 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4 | 6, 8, 10, 12, 15, 20, 30 | Ultra-low crossing profile (0.0157 inch for the 1-mm diameter balloon) | |
| Teleflex | Pantera Leo | 14 | 18–20 | 0.014 | 145 | 5 | 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 | 8, 12, 15, 20, 30 | Noncompliant balloon | |
| Teleflex | Pantera Pro | 7 | 14 | 0.014 | 140 | 5 | 1.25, 1.5, 2, 2.5, 3, 3.5, 4 | 6, 10, 15, 20, 25, 30 | Balloon and tip coating: 1.25–2 mm hydrophilic; 2.5–4 mm hydrophobic | |
| SMT Technologies Pvt. Ltd. | Pipit NC | 12 | 20 | 0.014 | 140 | 5 | 2, 2.25, 2.5, 2.75, 3, 3.5, 4, 4.5 | 6, 8, 10, 12, 15, 20, 25, 29 | Noncompliant dilatation catheter | |
| SMT Technologies Pvt. Ltd. | Pipit SC | 6 | 16 | 0.014 | 140 | 5 | 2, 2.25, 2.5, 2.75, 3, 3.5, 4, 4.5 | 9, 13, 15, 17, 20, 25, 29, 37, 41 | Semicompliant dilatation catheter | |
| BrosMed Medical | POT PTCA NC Balloon Dilatation Catheter | 12 | 20 (Ø, 4.5–5 mm), 22 (Ø, 2.25–4 mm) | 0.014 | 140 | 5 (Ø, 2.25–4 mm), 6 (Ø, 4.5–5 mm) | 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 | 6, 8, 10, 12, 15 | A dedicated balloon for proximal optimization technique and distal optimization technique; extra short balloon shoulder is as short as 0.6 mm; tip entry profile is as low as 0.016 inch | |
| Alvimedica | Pro HP | 6 | 18/20 | 0.014 | 142 | 5 (GC compatibility) | 1.5, 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4 | 10, 15, 20, 30 | – | |
| Cordis | Raiden3 PTCA Balloon | 12 | 22 | 0.014 | 146 | 5 | 1.5, 1.75, 2, 2.25, 2.5, 3, 3.25, 3.5, 3.75, 4, 4.25, 4.5 | 8, 10, 13, 15, 20, 30 | High-quality Japanese balloon design, ultra–low-profile postdilatation balloon | |
| Balton | River | 8 | 18 | 0.014 | 140 | 5 | 1.25–4 | 10–40 | – | |
| Balton | River CTO | 8 | 18 | 0.014 | 140 | 5 | 0.75–1.25 | 10–40 | CTO balloon catheters | |
| Terumo Europe | Ryujin Plus | 6 (608 kPa) | 12 (1,216 kPa) for 3.5, 4 mm; 14 (1,419 kPa) for 1.25–3 mm | Entry profile: 0.0157 (0.4 mm) for 1.25 mm/10 mm, 0.0165 (0.42 mm) for other sizes; proximal outer shaft diameter: 0.026 (2 F) | 145 | – | 1.25, 1.5, 2, 2.25 2.5, 2.75, 3, 3.5, 4 | 10, 15, 20, 30, 40 | Flexible distal shaft and hydrophilic coating for improved trackability; low profile enables kissing-balloon technique in 6-F large lumen (> 0.070 inch, 1.8 mm) guiding catheter; fixed outer and inner tube prevents accordion phenomenon at the balloon part | |
| Terumo Europe | Ryujin Plus OTW | 6 (608 kPa) | 14 | Entry profile: 0.0169 (0.43 mm) | 135/148 | – | 1.25, 1.5, 2 | 10, 15, 20 | 148-cm long shaft is suitable for CART technique; stiff shaft designed for enhanced kink resistance; inner shaft material designed for smooth guidewire handling; durable hydrophilic coating | |
| B. Braun Melsungen AG | SeQuent NEO | 6 (balloon diameter, 2–4 mm), 10 (balloon diameter, 1.25–1.5 mm) | 14 (balloon diameter, 2–4 mm), 18 (balloon diameter, 1.25–1.5 mm) | 0.014 | 145 | 5 (standard guiding catheter), 6 (kissing compatibility) | 1.25, 1.5, 2, 2.25, 2.5, 2.75, 3, 3.5, 4 | 10, 15, 20, 25, 30 | – | |
| Simeks Medical | Simpass CTO RX PTCA Balloon Dilatation Catheter | 8 | 16 | 0.014 | 145 | 5 | 1, 1.25, 1.5, 2, 2.5 | 10, 12, 15, 20, 25, 30 | Exceptional crossing and opening performance at chronic total occlusions; low-profile, flexible yet robust balloon catheter structure | |
| Simeks Medical | Simpass NC/HP RX PTCA Balloon Dilatation Catheter | 12 | 20 | 0.014 | 145 | 5 | 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 4, 4.5, 5 | 6, 9, 12, 15, 20, 25, 30 | Noncompliant and high pressure; durable and tear-resistant balloon material; controlled balloon growth and accurate balloon sizes | |
| Simeks Medical | Simpass Plus RX PTCA Balloon Dilatation Catheter | 8 | 16 | 0.014 | 145 | 5 | 1.25, 1.5, 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 4, 4.5, 5, 6 | 10, 12, 15, 18, 20, 22, 24, 25, 27, 30, 32, 35, 40, 42 | Semicompliant; unique lesion crossability and recrossability with low-profile and flexible balloon; hydrophilic coating from tip to RX port for comfortable navigation | |
| Medtronic | Sprinter Legend RX | 6 (1.5 mm) | 12 (1.5 mm) | 0.016 | 142 | 5, 6 kissing-balloon technique compatible | 1.5 | 6, 10, 12, 15, 20 | – | |
| Medtronic | Sprinter Legend RX | 8 (2–4 mm) | 14 (2–4 mm) | 0.016 | 142 | 5, 6 kissing-balloon technique compatible (up to 3.5-mm balloon) | 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4 | 6, 10, 12, 15, 20, 25, 30 | – | |
| Terumo Europe | Tazuna | 6 (608 kPa) | 14 (1,419 kPa) | Entry profile: 0.0157 (0.4 mm) for 1.25–2.25/10 mm, entry profile: 0.0165 (0.42 mm) for 1.25–2.25/15–20 mm, 2.5–3 mm | 145 | – | 1.25, 1.5, 2, 2.25, 2.5, 2.75, 3 | 10, 15, 20 | Outstanding pushability; the midshaft construction balances flexibility and stiffness, maximizing the transmission force to the distal part; modified guidewire exit port for a more durable PTCA balloon in complex procedures; low profile and thicker hypotube (compared to Ryujin Plus) to enhance pushability and kink resistance; improved crossing performance; ultra-low entry profile (0.4 mm/0.016 inch) for most challenging lesions; a flexible and robust tip to cross tight lesions and stent struts; hydrophilic coating on the distal shaft to facilitate navigation through distal tortuous vessels and calcified lesions; superior rewrapping and recrossability; specially engineered triwrapped balloon for superior rewrapping performance to enhance recrossability | |
| Abbott | Trek OTW Coronary Dilatation Catheter | 8 | 14 | 0.014 | 145 | – | 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 | 6, 8, 12, 15, 20, 25, 30 | – | |
| Abbott | Trek RX Coronary Dilatation Catheter | 8 | 14 | 0.014 | 145 | – | 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 | 6, 8, 12, 15, 20, 25, 30 | – | |
| SMT Technologies Pvt. Ltd. | Wilma SC | 6 | 16 | 0.014 | 140 | 5 | 2, 2.25, 2.5, 2.75, 3, 3.5, 4, 4.5 | 9, 13, 15, 17, 20, 25, 29, 37, 41 | Semicompliant dilatation catheter | |
| iVascular | Xperience pro | 6 | 16 | 0.014 | 142 | 5 (for all diameters), 6 (for kissing-balloon technique) | 1.25, 1.5, 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 | 10, 15, 20, 25, 30, 40 | – |