B. Braun Interventional Systems, Inc.

824 Twelfth Ave., Bethlehem, PA 18018

PHONE: (610) 691-5400 | FAX: (610) 997-4255

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Balloons / Specialty Balloons

View Chart
Company Name Product Name Nominal Pressure (atm) Rated Burst Pressure (atm) Guidewire Compatibility (inch) Size (F) Sheath Compatibility (F) Shaft Length (cm) Balloon Diameters (mm) Balloon Lengths (cm)
B. Braun Interventional Systems, Inc. Corodyn A Angiographic Balloon Flotation Catheter Nominal inflated diameter: 8, 10, 12 mm Max injection pressure: 650, 700, 900 PSI – 5, 6, 7 – 50, 60, 80, 90, 110 8, 10, 12 –
B. Braun Interventional Systems, Inc. BIB Catheter 1–3.5 2–7 0.035 8, 9, 11 8, 9, 10, 11, 16 110 12, 14, 15, 16, 18, 20, 22, 24, 26, 28, 30 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6, 6.5
B. Braun Interventional Systems, Inc. Z-6 Atrioseptostomy Catheter – 1, 2 mL (maximum inflation volume) 0.021 5 6 50 9.5, 13.5 0.95, 1.35
B. Braun Interventional Systems, Inc. Z-5 Atrioseptostomy Catheter – 1, 2 mL (maximum inflation volume) 0.014, 0.021 4, 5 5, 6 50 9.5, 13.5 0.95, 1.35
B. Braun Interventional Systems, Inc. PTS-X Sizing Balloon Up to 0.75 Up to 1.5 0.035 – 8, 9 80, 110 20, 25, 30, 35, 40 3, 4, 5
B. Braun Interventional Systems, Inc. PTS Sizing Balloon Up to 0.75 Up to 1.5 0.035 – 8, 9 80 20, 25, 30, 40 3, 4, 5
B. Braun Interventional Systems, Inc. Mini Ghost PTA Catheter Up to 10 Up to 20 0.018 3.5 4 40, 80, 120, 150 2, 3, 4, 5, 6 1, 2, 3, 4, 6, 8, 10
B. Braun Interventional Systems, Inc. Corodyn P1 Monitoring Wedge Pressure Balloon Flotation Catheter Nominal inflated diameter: 8, 10, 12 mm Max. balloon inflation capacity: 0.75, 1.25, 1.5 mL 0.025, 0.038 5, 6, 7 – 60, 110 8, 10, 12 –

Advertisement

Advertisement

Balloons / Valvuloplasty Balloons

View Chart
Company Name Product Name Catheter Size (F) Catheter Length (cm) Balloon Dilation Range (mm) Maximum Diameter (mm)
B. Braun Interventional Systems, Inc. Nucleus-X Balloon Aortic & Pulmonic Valvuloplasty Catheter 10–14 110 18–30 30
B. Braun Interventional Systems, Inc. Tyshak II Balloon Dilation Catheter 4–10 70, 90, 100 4–30 30
B. Braun Interventional Systems, Inc. Tyshak Mini Pediatric PTV Balloon Dilation Catheter 2.5, 3.5 65 4–10 10
B. Braun Interventional Systems, Inc. Tyshak Nucleus PTV Catheters 6–8 100 14–25 25
B. Braun Interventional Systems, Inc. Z-Med Balloon Dilatation Catheters 7–11 75, 85, 100, 120 14–40 40
B. Braun Interventional Systems, Inc. Z-Med II Balloon Dilatation Catheters 5–11 85, 100, 110, 120 4–30 30
B. Braun Interventional Systems, Inc. Z-Med II-X PTV Dilatation Catheter 6–11 100 8–30 30
B. Braun Interventional Systems, Inc. Z-Med-X PTV Dilatation Catheter 6–9 100 12–30 30

Catheters / Angiographic Catheters

View Chart
Company Name Product Name Type (Braided/Nonbraided) Size (F) Length (cm) Guidewire Compatibility (inch) Radiopaque Tip (Yes/No) Variety of Selective Shapes
B. Braun Interventional Systems, Inc. Multi-Track Nonbraided 3, 4, 5, 6 80, 100 0.025, 0.035 Yes Straight
B. Braun Interventional Systems, Inc. Corodyn A Angiographic Balloon Flotation Catheter Nonbraided 5, 6, 7 50, 60, 80, 90, 110 – Yes –

Sheaths / Special Access Sheaths

View Chart
Company Name Product Name Size (F) Length (cm) Guidewire Compatibility (inch) Curved or Straight Radiopaque Tip (Yes/No) Type of Special Access
B. Braun Interventional Systems, Inc. Accel Access 3-Piece Introducer System 6 20 ≤ 0.038 Straight Yes A three-piece introducer consisting of a stiffening stylet and dilator assembly that accepts a 0.018-inch guidewire and a sheath that can accommodate a ≤ 0.038-inch guidewire and an 0.018-inch guidewire simultaneously; entire length of the sheath is radiopaque and hydrophilic coated, and contains a radiopaque marker band at the distal tip; for percutaneous introduction and placement of catheters and guidewires for vascular and nonvascular applications
B. Braun Interventional Systems, Inc. D'Vill Introducer 12 30, 65, 85 0.035 Straight Yes Long-length, kink-resistant hemostasis introducer
B. Braun Interventional Systems, Inc. Micro-Introducer Kits: Regular and Stiff 4, 5 10 0.018 X 40 cm Straight No Microaccess
B. Braun Interventional Systems, Inc. Tear Away Introducer Sheaths and Kits 4–16 7, 10, 14, 30, 44 0.018 X 45 cm, 0.038 X 50 cm Straight No Designed for the introduction of catheters into the vasculature; full kits or separate sterile sheaths available

Sheaths / Standard Sheaths

View Chart
Company Name Product Name Size (F) Length (cm) Guidewire Compatibility (inch) Curved or Straight Radiopaque Tip (Yes/No)
B. Braun Interventional Systems, Inc. Elite HV Hemostasis Introducer Kits 3–7 7 0.018, 0.021 Straight With or without
B. Braun Interventional Systems, Inc. Occlutech Delivery Set III 6, 7, 8, 9, 10, 11, 12, 14 Sheath: 79, 1100; loader: 8.5, 12.5, 16.5 – 45°, 180° Yes

Structural Heart / Septal Occluders

View Chart
Company Name Product Name Recommended Size of Introducer (F) Recommended Diameter of Defect for Device (mm) Device Size (mm) Delivery Device Length (cm) US FDA Indicated Use Comments
B. Braun Interventional Systems, Inc. Occlutech ASD Occluder 6-12 5-33 waist size 6-33 120 Intended for transcatheter closure of ostium secundum-type atrial septal defects -

Wires / Interventional Access Wires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type Coating Type (Hydrophilic or Hydrophobic) Comments
B. Braun Interventional Systems, Inc. Guidewires Mandrel 0.018 40, 60, 80, 180, 300 Straight, angled – Available in a variety of configurations in stainless steel or nitinol guidewire and a stainless steel, platinum, or gold tip

Other Devices / Closed Fluid Systems

View Chart
Company Name Product Name Access to Saline Access to Waste Access to Contrast Fittings
B. Braun Interventional Systems, Inc. Dual-Line Fluid Collection System Yes No Yes Female luer lock
B. Braun Interventional Systems, Inc. Single-Line Fluid Collection System Yes No Yes Female luer lock

Other Devices / Occlusion Devices

View Chart
Company Name Product Name Type Position US FDA Indicated Use
B. Braun Interventional Systems, Inc. Nit-Occlud PDA Coil System for PDA Closure Premounted coil system for the closure of small to medium sized PDA types PDA (Patent Ductus Arteriosus) A permanently implanted prothesis indicated for percutaneous, transcatheter closure of small to moderate size patent ductus arteriosus with a minimum angiographic diameter < 4 mm
B. Braun Interventional Systems, Inc. Occlutech ASD Occluder Percutaneous transcatheter closure of ostium secundum atrial septal defects Ostium secundum atrial septal defects Intended for the transcatheter closure of ostium secundum-type ASD

Stents / Covered Stents

View Chart
Company Name Product Name Cover Material Stent Material/Design Guide Catheter Compatibility (F) Stent Diameter (mm) Stent Length (mm) US FDA Indicated Use
B. Braun Interventional Systems, Inc. Covered G-Armor Stent ePTFE Composed of platinum/iridium wire that is arranged in a unique “zig” pattern laser welded at each joint and then overbrazed with 24 k gold; available in 8 zig and 10 zig configurations for a high expansion range. 0.035 12–30 46, 52, 57, 63 Coartication of aorta
B. Braun Interventional Systems, Inc. Covered Mounted CP Stent ePTFE Composed of platinum/iridium wire that is arranged in a unique “zig” pattern laser welded at each joint and then overbrazed with 24 k gold; available in 8 zig and 10 zig configurations for a high expansion range 0.035 12–30 16, 22, 24, 28, 34, 39, 45, 50, 55, 60 Coarctation of the aorta; RVOT conduit disruption
B. Braun Interventional Systems, Inc. Mounted G-Armor Stent ePTFE Composed of platinum/iridium wire that is arranged in a unique “zig” pattern laser welded at each joint and then overbrazed with 24 k gold; available in 8 zig and 10 zig configurations for a high expansion range 0.035 12–30 46, 52, 57, 63 Coartication of aorta
B. Braun Interventional Systems, Inc. NuDEL CP Stent Delivery System ePTFE The Covered CP stent is made of platinum/iridium wire arranged in a “zig” pattern; every point of intersection is laser welded and brazed with 24 k gold; the stent covering is made of ePTFE 0.035 12–24 16, 22, 28, 34, 39, 45 Coarctation of the aorta; RVOT conduit disruption
B. Braun Interventional Systems, Inc. Covered CP Stent ePTFE Composed of platinum/iridium wire that is arranged in a unique “zig” pattern laser welded at each joint and then overbrazed with 24 k gold; available in 8 zig and 10 zig configurations for a high expansion range 0.035 12–30 16, 22, 28, 34, 39, 45, 50, 55, 60 Coarctation of the aorta; RVOT conduit disruption

More Categories:

Balloons Catheters Sheaths Stents Structural Heart Valves Wires Other Devices View All

Advertisement

Latest News


September 11, 2026

Medtronic Makes Strategic Investment in Pi-Cardia

September 11, 2026

IMDS’s NHanceIT Microcatheter for Complex PCI Launched in the United States 

September 10, 2026

Emboliner Embolic Protection System Cleared by FDA for TAVR

Most Read Articles


CT-Guided PCI: Toward Precision in Case Triage and Procedural Planning

By Yader Sandoval, MD, and Emmanouil S. Brilakis, MD, PhD

The Role of Cardiac CT for Successful TAVR Planning

By Harika Sai Dabbara, MD, and Lauren Sharan Ranard, MD, MS

enVast™: Engineered for Coronary Thrombectomy

By Marco Valgimigli, MD, PhD

Back to Top
CTO DES Hypertension Imaging Modalities PCI Pharmacology PE Radial Regulatory Structural Disease Valvular Interventions
Centers

Coding CTO DES Hypertension Imaging Modalities PCI Pharmacology Radial Regulatory Structural Disease Valvular Interventions Pulmonary Embolism

News• Current Issue• Archive• Device Guides• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Cardiac Interventions Today (ISSN 2572-5955 print and ISSN 2572-5963 online) is a publication dedicated to providing coverage of the latest developments in technology, techniques, clinical studies, and regulatory and reimbursement issues in the field of coronary and cardiac interventions.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. BlueSky-Circle
Endovascular Today
CIT-Logo-Color Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button