CIT-Logo-White Created with Sketch.
News Issue Archive Device Guide Calendar Subscribe Advertising

MENU

Device Guides
Trial Guide
Centers

Coding CTO DES Hypertension Imaging Modalities PCI Pharmacology Radial Regulatory Structural Disease Valvular Interventions

News Current Issue Archive Device Guide Calendar Subscribe Advertising About Contact Privacy Submissions
Coding CTO DES Hypertension Imaging Modalities PCI Pharmacology Radial Regulatory Structural Disease Valvular Interventions

Back to Top

Advertisement

Advertisement

EUROPEAN Company Directory


Asahi Intecc Co Ltd.

Strawinskylaan 527, World Trade Centre Tower B - 5th floor 1077 XX Amsterdam, The Netherlands

PHONE: +31 20 794 0642 | FAX: +31 20 794 0641

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Catheters / Microcatheters

View Chart
Company Name Product Name Type of Catheter Construction Proximal Size (F) Middle Size (F) Distal Size (F) Catheter Working Length (cm) Catheter Endhole ID (inch) Recommended Guidewire Size (inch) Radiopaque Tip (Yes/No) Hydrophilic Coating (Yes/No)
Asahi Intecc Co Ltd. Asahi Corsair Pro Stainless steel braiding 2.8 2.6 1.3 135, 150 0.015 0.014 Yes Yes
Asahi Intecc Co Ltd. Asahi Corsair Pro XS Stainless steel braiding 2.9 2.1 1.3 135, 150 0.015 0.014 Yes Yes
Asahi Intecc Co Ltd. Asahi Sasuke Double lumen catheter 3.2 2.5/3.3 1.5 145 0.016 0.014 Yes Yes
Asahi Intecc Co Ltd. Asahi Caravel Stainless steel braided 2.6 1.9 1.4 135, 150 0.016 0.014 Yes Yes

Advertisement

Advertisement

Wires / Interventional CTO/Specialty Wires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type Coating Type (Hydrophilic or Hydrophobic) Comments
Asahi Intecc Co Ltd. Fielder XT-R CTO 1st choice, polymer jacket, tapered 0.014 190, 300 Straight Hydrophilic with polymer jacket –
Asahi Intecc Co Ltd. Asahi Miracle Neo 3 Stainless steel, Act One core 0.014 190, 300 Square tip Hydrophilic, uncoated tip 3 gf tip load CTO guidewire
Asahi Intecc Co Ltd. Asahi Gladius MG Stainless steel, Act One, CTO guidewire 0.014 200, 300 1mm preshape Hydrophilic + polymer coating Controlled loop
Asahi Intecc Co Ltd. Ultimatebros 3 CTO 0.014 180, 300 Straight, J Hydrophilic; uncoated tip –
Asahi Intecc Co Ltd. Miracle 6 CTO 0.014 180, 300 Straight Hydrophobic –
Asahi Intecc Co Ltd. Miracle 3 CTO 0.014 180, 300 Straight Hydrophobic –
Asahi Intecc Co Ltd. Miracle 12 CTO 0.014 180, 300 Straight Hydrophobic –
Asahi Intecc Co Ltd. Fielder XT-A CTO 1st choice, polymer jacket, tapered 0.014, tapering to 0.010 190, 300 Straight Hydrophilic with polymer jacket –
Asahi Intecc Co Ltd. Fielder XT CTO 1st choice, polymer jacket, tapered 0.014, tapering to 0.009 180, 300 Straight Hydrophilic with polymer jacket –
Asahi Intecc Co Ltd. Extension 165 Extension wire 0.014 165 – – –
Asahi Intecc Co Ltd. Conquest Pro/Confianza Pro 9/12 CTO, 9 gf or 12 gf, tapered 0.014, tapering to 0.009 180 Straight Hydrophilic; uncoated tip –
Asahi Intecc Co Ltd. Asahi SUOH03 CTO, Act One, retrograde guidewire 0.014 190, 300 1 mm preshaped Hydrophilic 0.3-gf guidewire used to cross tortuous and angulated collaterals
Asahi Intecc Co Ltd. Asahi Gladius EX CTO, Act One 0.014 200, 300 1 mm preshaped Hydrophilic with polymer jacket Intermediate wire with Act One
Asahi Intecc Co Ltd. Asahi Gaia Next 3 CTO, Act One, tapered 0.014, tapering to 0.012 190, 300 1 mm preshaped Hydrophilic; uncoated tip –
Asahi Intecc Co Ltd. Asahi Gaia Next 2 CTO, Act One, tapered 0.014, tapering to 0.012 190, 300 1 mm preshaped Hydrophilic; uncoated tip –
Asahi Intecc Co Ltd. Asahi Gaia Next 1 CTO, Act One, tapered 0.014, tapering to 0.011 190, 300 1 mm preshaped Hydrophilic; uncoated tip –

Wires / Interventional Support Wires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type Coating Type (Hydrophilic or Hydrophobic) Comments
Asahi Intecc Co Ltd. Asahi Sion Blue ES Composite core 0.014 190, 300 Straight, J Hydrophilic; hydrophobic tip –
Asahi Intecc Co Ltd. Grand Slam Coil 0.014 180, 300 Straight, J Hydrophobic –

Wires / Interventional Workhorse Wires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type Coating Type (Hydrophilic or Hydrophobic) Comments
Asahi Intecc Co Ltd. Asahi Sion Composite core 0.014 190, 300 Straight, J, 1-mm preshape Hydrophilic –
Asahi Intecc Co Ltd. Asahi Sion Blue Composite core 0.014 190, 300 Straight, J, 1-mm preshape Hydrophilic; hydrophobic tip –
Asahi Intecc Co Ltd. Rinato/Prowater Coil 0.014 180, 300 Straight, J Hydrophilic; hydrophobic tip –
Asahi Intecc Co Ltd. Route/Prowater Flex Coil 0.014 180, 300 Straight, J Hydrophilic; hydrophobic tip –
Asahi Intecc Co Ltd. Asahi Sion black Composite core 0.014 190, 300 Straight, J, 1-mm preshape Hydrophilic + polymer coating –

More Categories:

Balloons Catheters Sheaths Stents Structural Heart Valves Wires Other Devices View All

Advertisement

Latest News


April 21, 2026

TECTONIC IDE Trial of Abbott’s Coronary IVL Device Completes Enrollment 

April 21, 2026

Conavi’s IVUS-OCT System for Intravascular Imaging Cleared by FDA

April 20, 2026

KingstronBio Announces First Implant of ProStyle M Transcatheter Mitral Valve System in Confirmatory Study

Most Read Articles


Advances in Wiring and Balloon Technology for Complex PCI

With Raghav Gattani, MD, and Lindsey Cilia, MD, FACC, FSCAI

For Suspected Coronary Calcium Nodules, What Is Your Step-by-Step PCI Strategy?

With Shrilla Banerjee, MD, FRCP, FESC; Jimmy L. Kerrigan, MD, FSCAI, FACC; and Aditya S. Bharadwaj, MD, FACC, FSCAI

New PCI Directions

By Louis Verreault-Julien, MD

Back to Top
Coding CTO DES Hypertension Imaging Modalities PCI Pharmacology Radial Regulatory Structural Disease Valvular Interventions
Centers

Coding CTO DES Hypertension Imaging Modalities PCI Pharmacology Radial Regulatory Structural Disease Valvular Interventions

News• Current Issue• Archive• Device Guides• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Cardiac Interventions Today (ISSN 2572-5955 print and ISSN 2572-5963 online) is a publication dedicated to providing coverage of the latest developments in technology, techniques, clinical studies, and regulatory and reimbursement issues in the field of coronary and cardiac interventions.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. BlueSky-Circle
Endovascular Today
CIT-Logo-Color Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button