CIT-Logo-White Created with Sketch.
News Issue Archive Device Guide Calendar Subscribe Advertising

MENU

Device Guides
Trial Guide
Centers

Coding CTO DES Hypertension Imaging Modalities PCI Pharmacology Radial Regulatory Structural Disease Valvular Interventions

News Current Issue Archive Device Guide Calendar Subscribe Advertising About Contact Privacy Submissions
Coding CTO DES Hypertension Imaging Modalities PCI Pharmacology Radial Regulatory Structural Disease Valvular Interventions

Back to Top

Advertisement

Advertisement

EUROPEAN Company Directory


Abbott

3200 Lakeside Drive, Santa Clara, CA 95054

PHONE: (408) 845-3000 | FAX: (800) 601-8874

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Balloons / PTCA Balloons

View Chart
Company Name Product Name Nominal Pressure (atm) Rated Burst Pressure (atm) Guidewire Compatibility (inch) Shaft Length (cm) Sheath Compatibility (F) Balloon Diameters (mm) Balloon Lengths (mm) Comments
Abbott Mini Trek RX Coronary Dilation Catheter 8 14 0.014 145 – 1.2, 1.5 6, 8, 12, 15, 20 –
Abbott Mini Trek RX Coronary Dilation Catheter 8 14 0.014 145 – 2 6, 8, 12, 15, 20, 25, 30 –
Abbott NC Trek OTW Coronary Dilatation Catheter 12 18 0.014 143 – 1.5, 2, 2.25, 2.75, 3.25 6, 8, 12, 15, 20 –
Abbott NC Trek OTW Coronary Dilatation Catheter 12 18 0.014 143 – 2.5, 3, 3.5 6, 8, 12, 15, 20, 25 –
Abbott NC Trek OTW Coronary Dilatation Catheter 12 18 0.014 143 – 3.75, 4, 4.5, 5 8, 12, 15, 20 –
Abbott NC Trek RX Coronary Dilatation Catheter 12 18 0.014 143 – 2.5, 3, 3.5 6, 8, 12, 15, 20, 25 –
Abbott NC Trek RX Coronary Dilatation Catheter 12 18 0.014 143 – 1.5, 2, 2.25, 2.5, 3.25 6, 8, 12, 15, 20 –
Abbott NC Trek RX Coronary Dilatation Catheter 12 18 0.014 143 – 3.75, 4, 4.5, 5 8, 12, 15, 20 –
Abbott Trek OTW Coronary Dilatation Catheter 8 14 0.014 145 – 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 6, 8, 12, 15, 20, 25, 30 –
Abbott Trek RX Coronary Dilatation Catheter 8 14 0.014 145 – 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 6, 8, 12, 15, 20, 25, 30 –
Abbott Mini Trek OTW II Coronary Dilation Catheter 8 14 0.014 145 – 1.2, 1.5, 2 6, 8, 12, 15, 20 –

Advertisement

Advertisement

Catheters / Specialty Catheters

View Chart
Company Name Product Name Catheter Size (F) Working Length (cm) Minimum Guiding Catheter ID (inch) Comments
Abbott Pacel Bipolar Pacing Catheter 4, 5, 6, 7 110 – Temporary pacing catheters available in straight, curved, flow-directed, and torque-controlled configurations

Sheaths / Special Access Sheaths

View Chart
Company Name Product Name Size (F) Length (cm) Guidewire Compatibility (inch) Curved or Straight Radiopaque Tip (Yes/No) Type of Special Access
Abbott Fast-Cath 4–14 5, 8.5, 12, 23, 30, 40, 45, 70, 75, 85, 90, 98, 110 0.021, 0.025, 0.032, 0.038 Straight, 30, 40, 48, 60, 5-, 7-cm J, GSPC No Small-vessel catheterizations, brachial artery introduction; introduction of thermal dilution and temporary pacing catheters; atherectomy, laser, valvuloplasty, and other large-diameter catheters; introduction and general management of electrophysiology catheters; biopsy procedures; other procedures in which longer sheath and curve aid physician technique
Abbott Ultimum 4, 5, 6, 7, 8, 12, 14, 16, 18, 20, 22 5, 8.5, 25, 30, 35 0.035, 0.038 Straight Yes, EV line Small-vessel and large-bore-diameter catheters

Sheaths / Standard Sheaths

View Chart
Company Name Product Name Size (F) Length (cm) Guidewire Compatibility (inch) Curved or Straight Radiopaque Tip (Yes/No)
Abbott Engage 4–9 12, 25 0.035, 0.038 Straight No
Abbott Ultimum 4–12, 14, 16, 18, 20, 22 5, 8.5, 12, 23, 25, 30, 35 0.035, 0.038 Straight Yes (EV line)

Stents / Coronary Balloon-Expandable Drug-Eluting Stents

View Chart
Company Name Product Name Drug Delivered Material Used Polymer Type Maximum Guidewire Size (inch) Introducer Size (F) Stent Diameter (mm) Stent Length (mm) Delivery System Length (cm) CE Mark Indications
Abbott Xience Alpine Everolimus-Eluting Coronary Stent System Everolimus Cobalt chromium Fluoropolymer 0.014 Minimum guide catheter size: 5 (RX and OTW): (≥ 0.056 inch/1.42 mm); 4-mm diameter: 6 (≥ 1.68 mm) 2.25, 2.5, 2.75, 3, 3.25, 3.5, 4 8, 12, 15, 18, 23, 28, 33, 38 145 –
Abbott Xience Sierra Everolimus-Eluting Coronary Stent System Everolimus Cobalt chromium Fluoropolymer 0.014 Minimum guide catheter size: 5 (RX and OTW: ≥ 0.056 inch/1.42 mm); 4-mm diameter: 6 (≥ 1.68 mm) 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 4 8, 12, 15, 18, 23, 28, 33, 38 145 Coronary
Abbott Xience Skypoint RX Everolimus-Eluting Coronary Stent System Everolimus Cobalt chromium Fluoropolymer 0.014 Minimum guide catheter size: 5 F/0.056/1.42 mm (2.25–4 mm, 8–38 mm); 6 F/0.070/1.78 mm (2.5–4 mm, 48 mm); 6 F/0.070/1.78 mm (4.5–5 mm, 12–33 mm) 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 4, 4.5, 5 8, 12, 15, 18, 23, 28, 33, 38, 48 145 Indicated for improving coronary artery luminal diameter in the following: (1) patients with symptomatic ischemic heart disease due to discrete de novo native coronary artery lesions; (2) for restoring coronary flow in patients experiencing acute myocardial infarction who present within 12 hours of symptom onset; (3) for the treatment of patients with concomitant diabetes, acute coronary syndrome, dual vessel lesions (two lesions in two different epicardial vessels), lesions residing within small coronary vessels; lesions where treatment results in the jailing of side branches (lesions with a side branch < 2 mm in diameter or an ostial stenosis < 50%); for the treatment of elderly patients (age ≥ 65) and for treatment of both men and women; (4) for treatment of patients with high bleeding risk (HBR) under dual anti-platelet therapy (DAPT) as short as 28 days; (5) for the treatment of patients presenting with in-stent restenosis in coronary artery lesions; chronic total occluded coronary artery lesions (defined as coronary artery lesions with TIMI flow 0 and lasting longer than 3 months); coronary artery bifurcation lesions and left main coronary artery lesions; in all cases, the treated lesion length should be less than the nominal stent length (8, 12, 15, 18, 23, 28, 33, or 38 mm) with a reference vessel diameter of ≥ 2 mm and ≤ 5.25 mm

Stents / Coronary Balloon-Expandable Stents

View Chart
Company Name Product Name Material Used Maximum Guidewire Size (inch) Introducer Size (F) Stent Diameter (mm) Stent Length (mm) Delivery System Length (cm) Comments
Abbott Multi-Link 8 LL Coronary Stent System Cobalt chromium 0.014 – 3, 3.5, 4 33, 38 143 –

Structural Heart / Left Atrial Appendage Closure

View Chart
Company Name Product Name Delivery System Name Available Device Sizes (mm) Delivery Access Delivery System OD (F) Access System OD (F) Access System Sheath Length (cm) Available Access System Configurations Device Frame Material Membrane Material CE Mark Indications
Abbott Amplatzer Amulet – 16, 18, 20, 22, 25, 28, 31, 34 – 12–14 – – – – – –
Abbott Amplatzer Cardiac Plug – 16, 18, 20, 22, 24, 26, 28, 30 – 9–13 – – – – – –

Structural Heart / Septal Occluders

View Chart
Company Name Product Name Recommended Size of Introducer (F) Recommended Diameter of Defect for Device (mm) Device Size (mm) Delivery Device Length (cm) CE Mark Indications Comments
Abbott Amplatzer Duct Occluder 5–7-F TorqVue Delivery Systems (device size determines delivery sheath selection) Ability to close ductus 3–12 mm in diameter; ≥ 5 mm in length 5/4, 6/4, 8/6, 10/8, 12/10 (device diameter at descending aorta/device diameter at pulmonary artery) 60 (5–7 F), 80 (6–7 F) – Nitinol and polyester construction allows its use on varied PDA shapes and size
Abbott Amplatzer Septal Occluder 6–12-F TorqVue Delivery Systems (device size determines delivery sheath selection) Ability to close 4–38-mm defects; 40-mm device not available in the United States 4–38 (waist diameter ASD) 60, 80 – Low-profile, nitinol and polyester construction; device waist fills defect for optimal fit and occlusion; endothelialization process promotes low thrombogenicity; low risk of erosion
Abbott Amplatzer PFO Occluder 8–9-F TorqVue Delivery Systems (device size determines delivery sheath) Device sizes available 18–35 mm; size of the device based on PFO morphology while taking into consideration the distances from the PFO to the aortic root and SVC 18, 25, 30,* 35 60, 80 – Nitinol and polyester construction, recapturable and repositionable, self centering; *30-mm device not available in United States
Abbott Amplatzer Multi-Fenestrated Septal Occluder - Cribriform 8–10-F TorqVue Delivery Systems (device size determines delivery sheath selection) Shortest distance from defect to aortic root or distance from defect to superior vena cava orifice: 18-mm device for distances between 9–12.4 mm, 25-mm device for distances 12.5 mm and 14.9 mm, 30-mm device for distances between 15–17.4 mm, and 35-mm device for distances ≥ 17.5 mm; do not implant if defect is < 9 mm 18, 25, 30, 35 60, 80 – Nitinol and polyester construction; thin waist offers optimal fit and occlusion of the multifenestrated atrial septal defect
Abbott Amplatzer Duct Occluder II 4–5-F TorqVue Low Profile Delivery Systems (device size determines delivery sheath selection) Ability to close ductus 2.5–5.5 mm in diameter; ≥ 5 mm in length 3–4, 3–6, 4–4, 4–6, 5–4, 5–6, 6–4, 6–6 (waist diameter–device length) 60, 80 – Fabric-free technology allows for lower-profile device and delivery systems; three articulated lobes create six planes of occlusion
Abbott Amplatzer Muscular VSD Occluder 6–9-F TorqVue Delivery Systems (device size determines delivery sheath selection) Ability to close 4–18-mm defects 4–18 (waist diameter VSD) 60 (6–8 F), 80 (6–9 F) – Nitinol and polyester fabric in the device waist and discs provide for rapid occlusion properties

Valves / Transcatheter Aortic Valve Implantation

View Chart
Company Name Product Name Valve Diameter (mm) Valve Height (mm) Valve Annulus Size Range (mm) Valve Frame Material Valve Leaflet Material Valve Anticalcification Process Delivery System Name Delivery Access Delivery System Deployment Type Delivery System Size (F) Delivery System Working Length (cm) CE Mark Indications Comments
Abbott Navitor TAVI System 23, 25, 27, 29 47–48 19–27 Nitinol Bovine pericardium Linx AC Technology FlexNav Delivery System Transfemoral and subclavian/axillary Self-expanding 14, 15 (ID) 107 High/extreme –
Abbott Portico With FlexNav TAVI System 23, 25, 27, 29 47–51 19–27 Nitinol Bovine pericardium Linx AC Technology FlexNav Delivery System Transfemoral and subclavian/axillary Self-expanding 14, 15 (ID) 107 High/extreme –

Valves / Transcatheter Mitral Valve Repair

View Chart
Company Name Product Name Delivery System Name Delivery Access Delivery System Size (F) Delivery System Working Length (cm) CE Mark Indications Comments
Abbott MitraClip Percutaneous Mitral Valve* Repair System Steerable Guide Catheter Transfemoral 22 (septal crossing diameter), 24 (OD) 80 – *Valve and delivery systems are not available for individual sale

Wires / Diagnostic Wires

View Chart
Company Name Product Name Type (Fixed Core or Movable Core) Diameter (inch) Length (cm) Tip Type Coating Type (Hydrophilic or Hydrophobic) Comments
Abbott TigerWire Steerable 0.035 150, 180, 260, 300 Standard, straight; floppy, exchanged, angled MicroGlide coated Unique flexibility zones offering supportive wire design for efficient tracking and positioning through tortuous vasculature; flexible, soft atraumatic tip enables access to target lesions
Abbott HydroSteer Nitinol core, long-taper core 0.018, 0.035, 0.038 150, 180, 260 Straight, angled, J Hydrophilic Excellent steerability for improved maneuvering through tortuous vessels, lubricious hydrophilic coating over a nitinol wire to reduce friction and enhance navigation through difficult vasculature
Abbott GuideRight Fixed core 0.021, 0.025, 0.028, 0.030, 0.032, 0.035, 0.038, 0.065 50, 80, 150, 180, 260 1.5-, 3-, 6-, 15-mm J, standard, firm, Bentson, Rosen, Newton LT, Amplatz, super stiff, double distal ends MicroGlide coated Stainless steel precision coil winding with internal safety design for reliability and control; proprietary surface finishing for lasting lubricity
Abbott GuideRight Movable core 0.035, 0.038 150 Standard, Amplatz, straight, 3-mm J MicroGlide coated Stainless steel precision coil winding with internal safety design for reliability and control; proprietary surface finishing for lasting lubricity

Wires / Interventional Access Wires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type Coating Type (Hydrophilic or Hydrophobic) Comments
Abbott HT Pilot 50 Tortuous anatomy 0.014 190, 300 Straight, J Hydrophilic –
Abbott HT Whisper ES Tortuous anatomy 0.014 190, 300 Straight, J Hydrophilic –
Abbott HT Whisper LS Tortuous anatomy 0.014 190, 300 Straight, J Hydrophilic –
Abbott HT Whisper MS Tortuous anatomy 0.014 190, 300 Straight, J Hydrophilic –

Wires / Interventional CTO/Specialty Wires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type Coating Type (Hydrophilic or Hydrophobic) Comments
Abbott HT Cross-It (100XT, 200XT, 300XT, 400XT) Tortuous anatomy 0.014 190, 300 Straight, J Hydrophilic –
Abbott HT Wiggle Specialty wire 0.014 190, 300 Straight Hydrophobic –
Abbott HT Standard Challenging lesions 0.014 190, 300 Straight, J Hydrophilic or hydrophobic –
Abbott HT Progress 80 CTO 0.014 190, 300 Straight Hydrophilic –
Abbott HT Progress 40 CTO 0.014 190, 300 Straight Hydrophilic –
Abbott HT Progress 140T CTO 0.014 190, 300 Straight with taper Hydrophilic –
Abbott HT Progress 120 CTO 0.014 190, 300 Straight Hydrophilic –
Abbott HT Pilot 200 CTO 0.014 190, 300 Straight, J Hydrophilic –
Abbott HT Pilot 150 CTO 0.014 190, 300 Straight, J Hydrophilic –
Abbott HT Progress 200T CTO 0.014 190, 300 Straight with taper Hydrophilic –

Wires / Interventional Support Wires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type Coating Type (Hydrophilic or Hydrophobic) Comments
Abbott HT All Star Extra support 0.014 190, 300 Straight, J Hydrophobic –
Abbott HT Balance Heavyweight Extra support 0.014 190, 300 Straight, J Hydrophilic –
Abbott HT Extra S'Port Extra support 0.014 190, 300 Straight, J Hydrophobic –
Abbott HT Iron Man Extra support 0.014 190, 300 Straight, J Hydrophobic –
Abbott HT Powerturn Extra support 0.014 190, 300 Straight, J Hydrophilic –

Wires / Interventional Workhorse Wires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type Coating Type (Hydrophilic or Hydrophobic) Comments
Abbott HT Floppy II ES Frontline 0.014 190, 300 Straight, J Hydrophilic and hydrophobic –
Abbott HT VersaTurn Frontline 0.014 190, 300 Straight, J Hydrophilic –
Abbott HT TurnTrac Frontline 0.014 190, 300 Straight, J Hydrophilic –
Abbott HT Traverse Frontline 0.014 190, 300 Straight, J Hydrophilic –
Abbott HT Powerturn Ultra Flex Frontline 0.014 190, 300 Straight, J Hydrophilic –
Abbott HT Powerturn Flex Frontline 0.014 190, 300 Straight, J Hydrophilic –
Abbott HT Balance Middleweight Universal II Frontline 0.014 190, 300 Straight, J Hydrophilic –
Abbott HT Balance Middleweight Universal Frontline 0.014 190, 300 Straight, J Hydrophilic –
Abbott HT Balance Middleweight Elite Frontline 0.014 190, 300 Straight, J Hydrophilic –
Abbott HT Balance Middleweight Frontline 0.014 190, 300 Straight, J Hydrophilic and hydrophobic –
Abbott HT Balance Frontline 0.014 190, 300 Straight, J Hydrophilic and hydrophobic –
Abbott HT Advance Frontline 0.014 190, 300 Straight, J Hydrophilic –
Abbott HT Floppy II Frontline 0.014 190, 300 Straight, J Hydrophilic and hydrophobic –

Other Devices / Assisted Compression Devices

View Chart
Company Name Product Name Type Puncture Size (F) Maximum Wire Compatibility Comments
Abbott RadiStop Mechanical compression device All All Sturdy support plate provides comfortable and efficient positioning of the wrist before, during, and after the procedure; transparent material allows for easy and correct placement
Abbott FemoStop II Plus Mechanical compression device All All Femoral compression system allows for precise placement and pressure management, and improves staff efficiency; reusable device arch and manometer to save on product and packaging materials
Abbott FemoStop Gold Mechanical compression device All All Fully integrated femoral compression system allows for greater ease of use, precise placement, and pressure management; improves staff efficiency and reduces risk of cross-contamination

Other Devices / Biopsy Forceps

View Chart
Company Name Product Name Shaft OD (F) Length (cm) Approach Shapeable Tip (Yes/No)
Abbott Procure Endomyocardial Biopsy Forceps 5.4, 7 50, 105 Femoral, internal jugular Yes

Other Devices / Closure Devices

View Chart
Company Name Product Name Type Puncture Size (F) Maximum Wire Compatibility (inch) CE Mark Indications Comments
Abbott Perclose ProGlide Suture Common femoral artery 5–21 (max OD, 26); common femoral vein 5–24 (max OD, 29) 0.038 Common femoral artery (5–21 F) and vein (5–24 F) access sites Provides secure repair with pretied polypropylene monofilament suture, ability to maintain wire access, minimal intravascular footprint with no reaccess restrictions; broadest indication for both femoral arterial and venous access
Abbott Prostar XL Suture 8.5–24 0.038 Common femoral artery access sites Provides secure repair with two braided sutures, ability to maintain wire access with minimal intravascular footprint
Abbott StarClose SE Nitinol clip 5–6 0.038 Common femoral artery (5–6 F) access sites Utilizes an extravascular nitinol clip to provide immediate repair, simple to use; hemostasis can be challenged and confirmed on the table

Other Devices / FFR Technologies

View Chart
Company Name Product Name Type (Fixed Core/Movable Core) Diameter (inch) Length (cm) Tip Type Antithrombogenic (Yes/No) Comments
Abbott PressureWire X Guidewire Fixed core 0.014 175 Straight Yes, PTFE coated Fully integrated, wireless PressureWire system when used with compatible hemodynamic systems; provides FFR measurement on Ilumien, Ilumien Optis, Optis Mobile, and Optis Integrated systems

Other Devices / Optical Coherence Tomography

View Chart
Company Name Product Name Imaging Diameter (mm) Catheter Usable Length (cm) Maximum Guidewire (inch) Minimum Guide Catheter ID (F) Shaft Distal Section (F) Comments
Abbott Dragonfly OpStar Intravascular Imaging Catheter 2–3.5 135 0.014 6 2.7 Compatible with Ultreon Software and Aptivue Software (E.5.1 software or higher)
Abbott Dragonfly Optis Intravascular Imaging Catheter 2–3.5 135 0.014 6 2.7 Works with the Ilumien, Ilumien Optis, Optis Mobile, Optis Integrated, Optis Next systems, which also include FFR measurement via the PressureWire Aeris

Other Devices / Y-Connector/Hemostatic Valve

View Chart
Company Name Product Name Main Branch ID (F) Pressure Rating (psi) Connector Length (mm) Bleedback Control Valve (Yes/No) Lockable Bleedback Control Valve (Yes/No) Rotating Valve (Yes/No) Valve Rotations (Full Open to Full Close) Comments
Abbott CoPilot 7.3 400 77 Yes No Yes 2 –

More Categories:

Balloons Catheters Sheaths Stents Structural Heart Valves Wires Other Devices View All

Advertisement

Latest News


April 21, 2026

TECTONIC IDE Trial of Abbott’s Coronary IVL Device Completes Enrollment 

April 21, 2026

Conavi’s IVUS-OCT System for Intravascular Imaging Cleared by FDA

April 20, 2026

KingstronBio Announces First Implant of ProStyle M Transcatheter Mitral Valve System in Confirmatory Study

Most Read Articles


Advances in Wiring and Balloon Technology for Complex PCI

With Raghav Gattani, MD, and Lindsey Cilia, MD, FACC, FSCAI

For Suspected Coronary Calcium Nodules, What Is Your Step-by-Step PCI Strategy?

With Shrilla Banerjee, MD, FRCP, FESC; Jimmy L. Kerrigan, MD, FSCAI, FACC; and Aditya S. Bharadwaj, MD, FACC, FSCAI

New PCI Directions

By Louis Verreault-Julien, MD

Back to Top
Coding CTO DES Hypertension Imaging Modalities PCI Pharmacology Radial Regulatory Structural Disease Valvular Interventions
Centers

Coding CTO DES Hypertension Imaging Modalities PCI Pharmacology Radial Regulatory Structural Disease Valvular Interventions

News• Current Issue• Archive• Device Guides• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Cardiac Interventions Today (ISSN 2572-5955 print and ISSN 2572-5963 online) is a publication dedicated to providing coverage of the latest developments in technology, techniques, clinical studies, and regulatory and reimbursement issues in the field of coronary and cardiac interventions.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. BlueSky-Circle
Endovascular Today
CIT-Logo-Color Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button