Balloons / PTCA Balloons

View Chart
Company Name Product Name Nominal Pressure (atm) Rated Burst Pressure (atm) Guidewire Compatibility (inch) Shaft Length (cm) Sheath Compatibility (F) Balloon Diameters (mm) Balloon Lengths (mm) Comments
Philips AngioSculpt PTCA X Drug-Coated Scoring Balloon Catheter RX 8 Up to 20 0.014 137 6 2, 2.5, 3, 3.5 10, 15, 20 Indicated for the treatment of significant coronary artery stenosis, including in-stent restenosis for the purpose of improving myocardial perfusion
Philips AngioSculpt RX PTCA Scoring Balloon Catheter 8 Up to 20 0.014 137 6 2, 2.5, 3, 3.5 6, 10, 15 –

Advertisement

Advertisement

Balloons / Specialty Balloons

View Chart
Company Name Product Name Nominal Pressure (atm) Rated Burst Pressure (atm) Guidewire Compatibility (inch) Size (F) Sheath Compatibility (F) Shaft Length (cm) Balloon Diameters (mm) Balloon Lengths (cm)
Philips AngioSculpt RX PTCA Scoring Balloon Catheter 8 Up to 20 0.014 6 6 137 2, 2.5, 3, 3.5 6, 10, 15

Balloons / Drug-Coated Balloons

View Chart
Company Name Product Name Drug Type Drug Concentration (µg/mm2) Excipient Type Guidewire Compatibility (inch) Shaft Length (cm) Sheath Compatibility (F) Balloon Diameters (mm) Balloon Lengths (cm)
Philips AngioSculpt PTCA X Drug-Coated Scoring Balloon Catheter RX Paclitaxel 3 NDGA 0.014 137 6 2, 2.5, 3, 3.5 1, 1.5, 2

Other Devices / Coronary Atherectomy Devices

View Chart
Company Name Product Name Minimum Vessel Diameter (mm) Sheath Compatibility (F) Crossing Profile (inch) Working Length (cm) Tip Length (cm)
Philips ELCA Coronary Laser Atherectomy 0.9 mm X 80 RX Catheter 2 4 0.038 135 –
Philips ELCA Coronary Laser Atherectomy 1.4 mm RX Catheter 2.2 5 0.057 135 –
Philips ELCA Coronary Laser Atherectomy 1.7 mm RX Catheter 2.5 6 0.069 135 –
Philips ELCA Coronary Laser Atherectomy 2.0 mm RX Catheter 3 7 0.080 135 –

Other Devices / FFR Technologies

View Chart
Company Name Product Name Type (Fixed Core/Movable Core) Diameter (inch) Length (cm) Tip Type Antithrombogenic (Yes/No) Comments
Philips ComboWire Guidewire Fixed core 0.014 185 Straight Yes Measures pressure and flow simultaneously using pulsed-wave Doppler technology
Philips FloWire Doppler Guidewire Fixed core 0.014 175, 300 Straight, J-shaped Yes Measures flow using pulsed-wave Doppler technology
Philips Verrata Plus Pressure Guidewire Fixed core 0.014 185, 300 Straight, J-shaped Yes Integrated iFR, FFR, and IVUS on s5i, Core, and IntraSight systems; integrates to measure FFR with compatible hemodynamic systems
Philips Verrata Pressure Guidewire Fixed core 0.014 185, 300 Straight, J-shaped Yes Integrated iFR, FFR, and IVUS on s5i, Core, and IntraSight systems; integrates to measure FFR with compatible hemodynamic systems

Other Devices / Intravascular Ultrasound

View Chart
Company Name Product Name Imaging Diameter (mm) Catheter Usable Length (cm) Maximum Guidewire (inch) Minimum Guide Catheter ID (F) Shaft Distal Section (F) Minimum Sheath Diameter (F) Comments
Philips Eagle Eye Platinum Digital IVUS (coronary or peripheral) 20 150 0.014 5 (ID ≥ 0.056 inch) – 5 Highly deliverable plug-and-play IVUS with GlyDx hydrophilic coating, three radiopaque markers, VH IVUS, and ChromaFlo imaging
Philips Eagle Eye Platinum ST Digital IVUS (coronary or peripheral) 20 150 0.014 5 (ID ≥ 0.056 inch) – 5 Short-tip model: highly deliverable plug-and-play IVUS with GlyDx hydrophilic coating, three radiopaque markers, VH IVUS, and ChromaFlo imaging
Philips Refinity ST Rotational IVUS (coronary) 14 135 0.014 5 (ID: ≥ 0.056 inch) – 5 High frequency (45 MHz) rotational IVUS
Philips Revolution Rotational IVUS (coronary) 14 135 0.014 6 (ID ≥ 0.064 inch) – 6 High-frequency (45 MHz) rotational IVUS

More Categories:

Balloons Catheters Sheaths Stents Structural Heart Valves Wires Other Devices View All

Advertisement

Latest News


April 21, 2026

TECTONIC IDE Trial of Abbott’s Coronary IVL Device Completes Enrollment 

April 21, 2026

Conavi’s IVUS-OCT System for Intravascular Imaging Cleared by FDA

April 20, 2026

KingstronBio Announces First Implant of ProStyle M Transcatheter Mitral Valve System in Confirmatory Study

Most Read Articles


Advances in Wiring and Balloon Technology for Complex PCI

With Raghav Gattani, MD, and Lindsey Cilia, MD, FACC, FSCAI

For Suspected Coronary Calcium Nodules, What Is Your Step-by-Step PCI Strategy?

With Shrilla Banerjee, MD, FRCP, FESC; Jimmy L. Kerrigan, MD, FSCAI, FACC; and Aditya S. Bharadwaj, MD, FACC, FSCAI

New PCI Directions

By Louis Verreault-Julien, MD

Back to Top
Coding CTO DES Hypertension Imaging Modalities PCI Pharmacology Radial Regulatory Structural Disease Valvular Interventions
Centers

Coding CTO DES Hypertension Imaging Modalities PCI Pharmacology Radial Regulatory Structural Disease Valvular Interventions

News• Current Issue• Archive• Device Guides• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Cardiac Interventions Today (ISSN 2572-5955 print and ISSN 2572-5963 online) is a publication dedicated to providing coverage of the latest developments in technology, techniques, clinical studies, and regulatory and reimbursement issues in the field of coronary and cardiac interventions.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. BlueSky-Circle
Endovascular Today
CIT-Logo-Color Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button