View Chart| Company Name | Product Name | Catheter Tip OD (inch) | Wire Size (inch) | Working Length (cm) | Minimum Guiding Catheter ID (F) | Comments |
|---|---|---|---|---|---|---|
| Control Medical Technology | SPINR 5X | – | 0.014–0.035 | – | – | High-performance guidewire controller |
Advertisement
Advertisement
Other Devices / Mechanical Thrombectomy/Thrombolysis
View Chart| Company Name | Product Name | Sheath Compatibility (F) | Guidewire Compatibility (inch) | Working Length (cm) | Mode of Operation | US FDA Indicated Use |
|---|---|---|---|---|---|---|
| Control Medical Technology | Aspire Mechanical Thrombectomy Drive Unit | – | – | – | Mechanical thrombectomy drive unit, continuous and/or pulsed mechanical thrombectomy | High-performance thrombectomy pump and drive unit to improve thrombectomy performance |
Other Devices / Thrombus Aspiration Devices
View Chart| Company Name | Product Name | Type | Maximum Tip Diameter (mm) | Minimum Guide Catheter Size (F) | Catheter Length (cm) |
|---|---|---|---|---|---|
| Control Medical Technology | Control 10F Mechanical Thrombectomy System | Mechanical aspirator and 10-F OTW catheter with dilator for peripheral vasculature | 3.45 | 10 (sheath) | 90 |
| Control Medical Technology | Control 5F Mechanical Thrombectomy System | Mechanical aspirator and 5-F OTW catheter system for peripheral vasculature | 1.65 | 5 (sheath) | 135 |
| Control Medical Technology | Control 6F Mechanical Thrombectomy System | Mechanical aspirator and 6-F OTW catheter for peripheral vasculature | 1.91 | 6 (sheath) | 135 |
| Control Medical Technology | Control 7F Mechanical Thrombectomy System | Mechanical aspirator and 7-F OTW catheter with dilator for peripheral vasculature | 2.3 | 7 (sheath) | 90 |
| Control Medical Technology | Control 8F Mechanical Thrombectomy System | Mechanical aspirator and 8-F OTW catheter with dilator for peripheral vasculature | 2.85 | 8 (sheath) | 90 |
| Control Medical Technology | Control Mechanical Aspirator | Mechanical aspirator that connects to any thrombectomy catheter | Any catheter | Any guide catheter or sheath | Any length |
| Control Medical Technology | Control RX-LP Mechanical Thrombectomy System | Mechanical aspirator and rapid-exchange catheter system for coronary and peripheral vasculature | 1.70 | 6 (or 5-F sheath) | 136 |