High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal
–
Boston Scientific Corporation
AngioJet SpiroflexVG Thrombectomy Set
6
0.014
135
High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal
–
Boston Scientific Corporation
AngioJet XMI Thrombectomy Set
4
0.014
135
High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal
–
Control Medical Technology
Aspire Mechanical Thrombectomy Drive Unit
–
–
–
Mechanical thrombectomy drive unit, continuous and/or pulsed mechanical thrombectomy
–
Argon Medical Devices, Inc.
Cleaner 15
7
–
65, 135
Battery-operated, handheld drive unit initiates the mechanical rotation of an atraumatic, wall-contacting, 15-mm sinusoidal cortex wire for effective thrombus maceration
–
Argon Medical Devices, Inc.
Cleaner XT
6
–
65, 135
Battery-operated, handheld drive unit initiates the mechanical rotation of an atraumatic, wall-contacting, 9-mm sinusoidal vortex wire for effective thrombus maceration
The treatment offers a minimally invasive system for the acceleration of thrombus dissolution; the ultrasonic core generates a localized acoustic field that targets the entire thrombus, accelerating lytic dispersion by driving the drug deeper into the clot and unwinding the fibrin to expose plasminogen receptor sites
Intended for controlled and selective infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature; indicated for the treatment of pulmonary embolism with ≥ 50% clot burden in one or both main pulmonary arteries or lobar pulmonary arteries and evidence of right heart dysfunction based on right heart pressures (mean pulmonary artery pressure ≥ 25 mm Hg) or echocardiographic evaluation
Vesalio Inc.
enVast Thrombectomy System 4.0 X 30 mm
Can be delivered through catheters with ID as small as 0.021 (1.6 F)
Max: 0.018
Full length: 39 mm; working length: 30 mm
The Vesalio enVast mechanical thrombectomy system is positioned across the embolus or blood clot and is used to facilitate the restoration of blood flow and removal of the clot obstruction; 2 Drop Zones for clot capture and 1 flow restoration zone; maximal diameter: 4 mm; minimum microcatheter compatibility: 0.021-inch ID
Indicated for endovascular temporary use to restore blood flow in patients who are experiencing symptoms of thrombosis in the coronary vasculature; vessels with diameter > 2 mm and ≤ 3.5 mm
Vesalio Inc.
enVast Thrombectomy System 4.5 X 37 mm
Can be delivered through catheters with ID as small as 0.021 (1.6 F)
Max: 0.018
Full length: 57 mm; working length: 37 mm
The Vesalio enVast mechanical thrombectomy system is positioned across the embolus or blood clot and is used to facilitate the restoration of blood flow and removal of the clot obstruction; 2 Drop Zones for clot capture and 1 flow restoration zone; minimum microcatheter compatibility: 0.021-inch ID
Indicated for endovascular temporary use to restore blood flow in patients who are experiencing symptoms of thrombosis in the coronary vasculature; vessels with diameter > 2 and ≤ 4.5 mm; maximal diameter: 4.5 mm
Vesalio Inc.
enVast Thrombectomy System 4.5 X 46 mm
Can be delivered through catheters with ID as small as 0.021 (1.6 F)
Max: 0.018
Full length: 66 mm; working length: 46 mm
The Vesalio enVast mechanical thrombectomy system is positioned across the embolus or blood clot and is used to facilitate the restoration of blood flow and removal of the clot obstruction; 2 Drop Zones for clot capture and 1 flow restoration zone; maximal diameter: 4.5 mm; minimum microcatheter compatibility: 0.021-inch ID
Indicated for endovascular temporary use to restore blood flow in patients who are experiencing symptoms of thrombosis in the coronary vasculature; vessels with diameter > 2 and ≤ 4.5 mm
Vesalio Inc.
enVast Thrombectomy System 6.0 X 35 mm
Can be delivered through catheters with ID as small as 0.027 (2.06 F)
Max: 0.018
Full length: 55 mm; working length: 35 mm
The Vesalio enVast mechanical thrombectomy system is positioned across the embolus or blood clot and is used to facilitate the restoration of blood flow and removal of the clot obstruction; 2 Drop Zones for clot capture and 1 flow restoration zone; maximal diameter: 6 mm; minimum microcatheter compatibility: 0.027-inch ID
Indicated for endovascular temporary use to restore blood flow in patients who are experiencing symptoms of thrombosis in the coronary vasculature; vessels with diameter > 3.5 and ≤ 6 mm
Penumbra, Inc. (Peripheral Vascular)
Indigo System Catheter CAT RX
6 (guide catheter)
0.014
140
Mechanical extraction of thrombus/embolus with constant vacuum aspiration
As part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature
Penumbra, Inc. (Peripheral Vascular)
Indigo System Catheters: Lightning Flash 2.0
16
0.014–0.038
80–115
Lightning Flash Aspiration Tubing facilitates the transfer of vacuum between INDIGO Flash Aspiration Catheter and Penumbra Aspiration Pump while providing intermittent or continuous aspiration
The Indigo Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and for the treatment of pulmonary embolism; as part of the INDIGO Aspiration System, the INDIGO Sterile Aspiration Tubing is indicated to connect the INDIGO Aspiration Catheters to the Penumbra Aspiration Pump
Penumbra, Inc. (Peripheral Vascular)
Indigo System Separator SEPC4
–
–
200
Separator-assisted clot debulking, if needed
As part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature