Advertisement
Advertisement
Abbott
3200 Lakeside Drive, Santa Clara, CA 95054
PHONE: (408) 845-3000 | FAX: (800) 601-8874
Balloons / PTCA Balloons
View Chart| Company Name | Product Name | Nominal Pressure (atm) | Rated Burst Pressure (atm) | Guidewire Compatibility (inch) | Shaft Length (cm) | Sheath Compatibility (F) | Balloon Diameters (mm) | Balloon Lengths (mm) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| Abbott | Mini Trek RX Coronary Dilation Catheter | 8 | 14 | 0.014 | 145 | – | 1.2, 1.5 | 6, 8, 12, 15, 20 | – |
| Abbott | Mini Trek RX Coronary Dilation Catheter | 8 | 14 | 0.014 | 145 | – | 2 | 6, 8, 12, 15, 20, 25, 30 | – |
| Abbott | NC Trek OTW Coronary Dilatation Catheter | 12 | 18 | 0.014 | 143 | – | 1.5, 2, 2.25, 2.75, 3.25 | 6, 8, 12, 15, 20 | – |
| Abbott | NC Trek OTW Coronary Dilatation Catheter | 12 | 18 | 0.014 | 143 | – | 2.5, 3, 3.5 | 6, 8, 12, 15, 20, 25 | – |
| Abbott | NC Trek OTW Coronary Dilatation Catheter | 12 | 18 | 0.014 | 143 | – | 3.75, 4, 4.5, 5 | 8, 12, 15, 20 | – |
| Abbott | NC Trek RX Coronary Dilatation Catheter | 12 | 18 | 0.014 | 143 | – | 2.5, 3, 3.5 | 6, 8, 12, 15, 20, 25 | – |
| Abbott | NC Trek RX Coronary Dilatation Catheter | 12 | 18 | 0.014 | 143 | – | 1.5, 2, 2.25, 2.5, 3.25 | 6, 8, 12, 15, 20 | – |
| Abbott | NC Trek RX Coronary Dilatation Catheter | 12 | 18 | 0.014 | 143 | – | 3.75, 4, 4.5, 5 | 8, 12, 15, 20 | – |
| Abbott | Trek OTW Coronary Dilatation Catheter | 8 | 14 | 0.014 | 145 | – | 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 | 6, 8, 12, 15, 20, 25, 30 | – |
| Abbott | Trek RX Coronary Dilatation Catheter | 8 | 14 | 0.014 | 145 | – | 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5 | 6, 8, 12, 15, 20, 25, 30 | – |
| Abbott | Mini Trek OTW II Coronary Dilation Catheter | 8 | 14 | 0.014 | 145 | – | 1.2, 1.5, 2 | 6, 8, 12, 15, 20 | – |
Advertisement
Advertisement
Catheters / Specialty Catheters
View Chart| Company Name | Product Name | Catheter Size (F) | Working Length (cm) | Minimum Guiding Catheter ID (inch) | Comments |
|---|---|---|---|---|---|
| Abbott | Pacel Bipolar Pacing Catheter | 4, 5, 6, 7 | 110 | – | Temporary pacing catheters available in straight, curved, flow-directed, and torque-controlled configurations |
Sheaths / Special Access Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip (Yes/No) | Type of Special Access |
|---|---|---|---|---|---|---|---|
| Abbott | Fast-Cath | 4–14 | 5, 8.5, 12, 23, 30, 40, 45, 70, 75, 85, 90, 98, 110 | 0.021, 0.025, 0.032, 0.038 | Straight, 30, 40, 48, 60, 5-, 7-cm J, GSPC | No | Small-vessel catheterizations, brachial artery introduction; introduction of thermal dilution and temporary pacing catheters; atherectomy, laser, valvuloplasty, and other large-diameter catheters; introduction and general management of electrophysiology catheters; biopsy procedures; other procedures in which longer sheath and curve aid physician technique |
| Abbott | Ultimum | 4, 5, 6, 7, 8, 12, 14, 16, 18, 20, 22 | 5, 8.5, 25, 30, 35 | 0.035, 0.038 | Straight | Yes, EV line | Small-vessel and large-bore-diameter catheters |
Sheaths / Standard Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip (Yes/No) |
|---|---|---|---|---|---|---|
| Abbott | Engage | 4–9 | 12, 25 | 0.035, 0.038 | Straight | No |
| Abbott | Ultimum | 4–12, 14, 16, 18, 20, 22 | 5, 8.5, 12, 23, 25, 30, 35 | 0.035, 0.038 | Straight | Yes (EV line) |
Stents / Coronary Balloon-Expandable Drug-Eluting Stents
View Chart| Company Name | Product Name | Drug Delivered | Material Used | Polymer Type | Maximum Guidewire Size (inch) | Introducer Size (F) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | CE Mark Indications |
|---|---|---|---|---|---|---|---|---|---|---|
| Abbott | Xience Alpine Everolimus-Eluting Coronary Stent System | Everolimus | Cobalt chromium | Fluoropolymer | 0.014 | Minimum guide catheter size: 5 (RX and OTW): (≥ 0.056 inch/1.42 mm); 4-mm diameter: 6 (≥ 1.68 mm) | 2.25, 2.5, 2.75, 3, 3.25, 3.5, 4 | 8, 12, 15, 18, 23, 28, 33, 38 | 145 | – |
| Abbott | Xience Sierra Everolimus-Eluting Coronary Stent System | Everolimus | Cobalt chromium | Fluoropolymer | 0.014 | Minimum guide catheter size: 5 (RX and OTW: ≥ 0.056 inch/1.42 mm); 4-mm diameter: 6 (≥ 1.68 mm) | 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 4 | 8, 12, 15, 18, 23, 28, 33, 38 | 145 | Coronary |
| Abbott | Xience Skypoint RX Everolimus-Eluting Coronary Stent System | Everolimus | Cobalt chromium | Fluoropolymer | 0.014 | Minimum guide catheter size: 5 F/0.056/1.42 mm (2.25–4 mm, 8–38 mm); 6 F/0.070/1.78 mm (2.5–4 mm, 48 mm); 6 F/0.070/1.78 mm (4.5–5 mm, 12–33 mm) | 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 4, 4.5, 5 | 8, 12, 15, 18, 23, 28, 33, 38, 48 | 145 | Indicated for improving coronary artery luminal diameter in the following: (1) patients with symptomatic ischemic heart disease due to discrete de novo native coronary artery lesions; (2) for restoring coronary flow in patients experiencing acute myocardial infarction who present within 12 hours of symptom onset; (3) for the treatment of patients with concomitant diabetes, acute coronary syndrome, dual vessel lesions (two lesions in two different epicardial vessels), lesions residing within small coronary vessels; lesions where treatment results in the jailing of side branches (lesions with a side branch < 2 mm in diameter or an ostial stenosis < 50%); for the treatment of elderly patients (age ≥ 65) and for treatment of both men and women; (4) for treatment of patients with high bleeding risk (HBR) under dual anti-platelet therapy (DAPT) as short as 28 days; (5) for the treatment of patients presenting with in-stent restenosis in coronary artery lesions; chronic total occluded coronary artery lesions (defined as coronary artery lesions with TIMI flow 0 and lasting longer than 3 months); coronary artery bifurcation lesions and left main coronary artery lesions; in all cases, the treated lesion length should be less than the nominal stent length (8, 12, 15, 18, 23, 28, 33, or 38 mm) with a reference vessel diameter of ≥ 2 mm and ≤ 5.25 mm |
Stents / Coronary Balloon-Expandable Stents
View Chart| Company Name | Product Name | Material Used | Maximum Guidewire Size (inch) | Introducer Size (F) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | Comments |
|---|---|---|---|---|---|---|---|---|
| Abbott | Multi-Link 8 LL Coronary Stent System | Cobalt chromium | 0.014 | – | 3, 3.5, 4 | 33, 38 | 143 | – |
Structural Heart / Left Atrial Appendage Closure
View Chart| Company Name | Product Name | Delivery System Name | Available Device Sizes (mm) | Delivery Access | Delivery System OD (F) | Access System OD (F) | Access System Sheath Length (cm) | Available Access System Configurations | Device Frame Material | Membrane Material | CE Mark Indications |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Abbott | Amplatzer Amulet | – | 16, 18, 20, 22, 25, 28, 31, 34 | – | 12–14 | – | – | – | – | – | – |
| Abbott | Amplatzer Cardiac Plug | – | 16, 18, 20, 22, 24, 26, 28, 30 | – | 9–13 | – | – | – | – | – | – |
Structural Heart / Septal Occluders
View Chart| Company Name | Product Name | Recommended Size of Introducer (F) | Recommended Diameter of Defect for Device (mm) | Device Size (mm) | Delivery Device Length (cm) | CE Mark Indications | Comments |
|---|---|---|---|---|---|---|---|
| Abbott | Amplatzer Duct Occluder | 5–7-F TorqVue Delivery Systems (device size determines delivery sheath selection) | Ability to close ductus 3–12 mm in diameter; ≥ 5 mm in length | 5/4, 6/4, 8/6, 10/8, 12/10 (device diameter at descending aorta/device diameter at pulmonary artery) | 60 (5–7 F), 80 (6–7 F) | – | Nitinol and polyester construction allows its use on varied PDA shapes and size |
| Abbott | Amplatzer Septal Occluder | 6–12-F TorqVue Delivery Systems (device size determines delivery sheath selection) | Ability to close 4–38-mm defects; 40-mm device not available in the United States | 4–38 (waist diameter ASD) | 60, 80 | – | Low-profile, nitinol and polyester construction; device waist fills defect for optimal fit and occlusion; endothelialization process promotes low thrombogenicity; low risk of erosion |
| Abbott | Amplatzer PFO Occluder | 8–9-F TorqVue Delivery Systems (device size determines delivery sheath) | Device sizes available 18–35 mm; size of the device based on PFO morphology while taking into consideration the distances from the PFO to the aortic root and SVC | 18, 25, 30,* 35 | 60, 80 | – | Nitinol and polyester construction, recapturable and repositionable, self centering; *30-mm device not available in United States |
| Abbott | Amplatzer Multi-Fenestrated Septal Occluder - Cribriform | 8–10-F TorqVue Delivery Systems (device size determines delivery sheath selection) | Shortest distance from defect to aortic root or distance from defect to superior vena cava orifice: 18-mm device for distances between 9–12.4 mm, 25-mm device for distances 12.5 mm and 14.9 mm, 30-mm device for distances between 15–17.4 mm, and 35-mm device for distances ≥ 17.5 mm; do not implant if defect is < 9 mm | 18, 25, 30, 35 | 60, 80 | – | Nitinol and polyester construction; thin waist offers optimal fit and occlusion of the multifenestrated atrial septal defect |
| Abbott | Amplatzer Duct Occluder II | 4–5-F TorqVue Low Profile Delivery Systems (device size determines delivery sheath selection) | Ability to close ductus 2.5–5.5 mm in diameter; ≥ 5 mm in length | 3–4, 3–6, 4–4, 4–6, 5–4, 5–6, 6–4, 6–6 (waist diameter–device length) | 60, 80 | – | Fabric-free technology allows for lower-profile device and delivery systems; three articulated lobes create six planes of occlusion |
| Abbott | Amplatzer Muscular VSD Occluder | 6–9-F TorqVue Delivery Systems (device size determines delivery sheath selection) | Ability to close 4–18-mm defects | 4–18 (waist diameter VSD) | 60 (6–8 F), 80 (6–9 F) | – | Nitinol and polyester fabric in the device waist and discs provide for rapid occlusion properties |
Valves / Transcatheter Aortic Valve Implantation
View Chart| Company Name | Product Name | Valve Diameter (mm) | Valve Height (mm) | Valve Annulus Size Range (mm) | Valve Frame Material | Valve Leaflet Material | Valve Anticalcification Process | Delivery System Name | Delivery Access | Delivery System Deployment Type | Delivery System Size (F) | Delivery System Working Length (cm) | CE Mark Indications | Comments |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Abbott | Navitor TAVI System | 23, 25, 27, 29 | 47–48 | 19–27 | Nitinol | Bovine pericardium | Linx AC Technology | FlexNav Delivery System | Transfemoral and subclavian/axillary | Self-expanding | 14, 15 (ID) | 107 | High/extreme | – |
| Abbott | Portico With FlexNav TAVI System | 23, 25, 27, 29 | 47–51 | 19–27 | Nitinol | Bovine pericardium | Linx AC Technology | FlexNav Delivery System | Transfemoral and subclavian/axillary | Self-expanding | 14, 15 (ID) | 107 | High/extreme | – |
Valves / Transcatheter Mitral Valve Repair
View Chart| Company Name | Product Name | Delivery System Name | Delivery Access | Delivery System Size (F) | Delivery System Working Length (cm) | CE Mark Indications | Comments |
|---|---|---|---|---|---|---|---|
| Abbott | MitraClip Percutaneous Mitral Valve* Repair System | Steerable Guide Catheter | Transfemoral | 22 (septal crossing diameter), 24 (OD) | 80 | – | *Valve and delivery systems are not available for individual sale |
Wires / Diagnostic Wires
View Chart| Company Name | Product Name | Type (Fixed Core or Movable Core) | Diameter (inch) | Length (cm) | Tip Type | Coating Type (Hydrophilic or Hydrophobic) | Comments |
|---|---|---|---|---|---|---|---|
| Abbott | TigerWire | Steerable | 0.035 | 150, 180, 260, 300 | Standard, straight; floppy, exchanged, angled | MicroGlide coated | Unique flexibility zones offering supportive wire design for efficient tracking and positioning through tortuous vasculature; flexible, soft atraumatic tip enables access to target lesions |
| Abbott | HydroSteer | Nitinol core, long-taper core | 0.018, 0.035, 0.038 | 150, 180, 260 | Straight, angled, J | Hydrophilic | Excellent steerability for improved maneuvering through tortuous vessels, lubricious hydrophilic coating over a nitinol wire to reduce friction and enhance navigation through difficult vasculature |
| Abbott | GuideRight | Fixed core | 0.021, 0.025, 0.028, 0.030, 0.032, 0.035, 0.038, 0.065 | 50, 80, 150, 180, 260 | 1.5-, 3-, 6-, 15-mm J, standard, firm, Bentson, Rosen, Newton LT, Amplatz, super stiff, double distal ends | MicroGlide coated | Stainless steel precision coil winding with internal safety design for reliability and control; proprietary surface finishing for lasting lubricity |
| Abbott | GuideRight | Movable core | 0.035, 0.038 | 150 | Standard, Amplatz, straight, 3-mm J | MicroGlide coated | Stainless steel precision coil winding with internal safety design for reliability and control; proprietary surface finishing for lasting lubricity |
Wires / Interventional Access Wires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type | Coating Type (Hydrophilic or Hydrophobic) | Comments |
|---|---|---|---|---|---|---|---|
| Abbott | HT Pilot 50 | Tortuous anatomy | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
| Abbott | HT Whisper ES | Tortuous anatomy | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
| Abbott | HT Whisper LS | Tortuous anatomy | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
| Abbott | HT Whisper MS | Tortuous anatomy | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
Wires / Interventional CTO/Specialty Wires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type | Coating Type (Hydrophilic or Hydrophobic) | Comments |
|---|---|---|---|---|---|---|---|
| Abbott | HT Cross-It (100XT, 200XT, 300XT, 400XT) | Tortuous anatomy | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
| Abbott | HT Wiggle | Specialty wire | 0.014 | 190, 300 | Straight | Hydrophobic | – |
| Abbott | HT Standard | Challenging lesions | 0.014 | 190, 300 | Straight, J | Hydrophilic or hydrophobic | – |
| Abbott | HT Progress 80 | CTO | 0.014 | 190, 300 | Straight | Hydrophilic | – |
| Abbott | HT Progress 40 | CTO | 0.014 | 190, 300 | Straight | Hydrophilic | – |
| Abbott | HT Progress 140T | CTO | 0.014 | 190, 300 | Straight with taper | Hydrophilic | – |
| Abbott | HT Progress 120 | CTO | 0.014 | 190, 300 | Straight | Hydrophilic | – |
| Abbott | HT Pilot 200 | CTO | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
| Abbott | HT Pilot 150 | CTO | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
| Abbott | HT Progress 200T | CTO | 0.014 | 190, 300 | Straight with taper | Hydrophilic | – |
Wires / Interventional Support Wires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type | Coating Type (Hydrophilic or Hydrophobic) | Comments |
|---|---|---|---|---|---|---|---|
| Abbott | HT All Star | Extra support | 0.014 | 190, 300 | Straight, J | Hydrophobic | – |
| Abbott | HT Balance Heavyweight | Extra support | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
| Abbott | HT Extra S'Port | Extra support | 0.014 | 190, 300 | Straight, J | Hydrophobic | – |
| Abbott | HT Iron Man | Extra support | 0.014 | 190, 300 | Straight, J | Hydrophobic | – |
| Abbott | HT Powerturn | Extra support | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
Wires / Interventional Workhorse Wires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type | Coating Type (Hydrophilic or Hydrophobic) | Comments |
|---|---|---|---|---|---|---|---|
| Abbott | HT Floppy II ES | Frontline | 0.014 | 190, 300 | Straight, J | Hydrophilic and hydrophobic | – |
| Abbott | HT VersaTurn | Frontline | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
| Abbott | HT TurnTrac | Frontline | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
| Abbott | HT Traverse | Frontline | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
| Abbott | HT Powerturn Ultra Flex | Frontline | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
| Abbott | HT Powerturn Flex | Frontline | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
| Abbott | HT Balance Middleweight Universal II | Frontline | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
| Abbott | HT Balance Middleweight Universal | Frontline | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
| Abbott | HT Balance Middleweight Elite | Frontline | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
| Abbott | HT Balance Middleweight | Frontline | 0.014 | 190, 300 | Straight, J | Hydrophilic and hydrophobic | – |
| Abbott | HT Balance | Frontline | 0.014 | 190, 300 | Straight, J | Hydrophilic and hydrophobic | – |
| Abbott | HT Advance | Frontline | 0.014 | 190, 300 | Straight, J | Hydrophilic | – |
| Abbott | HT Floppy II | Frontline | 0.014 | 190, 300 | Straight, J | Hydrophilic and hydrophobic | – |
Other Devices / Assisted Compression Devices
View Chart| Company Name | Product Name | Type | Puncture Size (F) | Maximum Wire Compatibility | Comments |
|---|---|---|---|---|---|
| Abbott | RadiStop | Mechanical compression device | All | All | Sturdy support plate provides comfortable and efficient positioning of the wrist before, during, and after the procedure; transparent material allows for easy and correct placement |
| Abbott | FemoStop II Plus | Mechanical compression device | All | All | Femoral compression system allows for precise placement and pressure management, and improves staff efficiency; reusable device arch and manometer to save on product and packaging materials |
| Abbott | FemoStop Gold | Mechanical compression device | All | All | Fully integrated femoral compression system allows for greater ease of use, precise placement, and pressure management; improves staff efficiency and reduces risk of cross-contamination |
Other Devices / Biopsy Forceps
View Chart| Company Name | Product Name | Shaft OD (F) | Length (cm) | Approach | Shapeable Tip (Yes/No) |
|---|---|---|---|---|---|
| Abbott | Procure Endomyocardial Biopsy Forceps | 5.4, 7 | 50, 105 | Femoral, internal jugular | Yes |
Other Devices / Closure Devices
View Chart| Company Name | Product Name | Type | Puncture Size (F) | Maximum Wire Compatibility (inch) | CE Mark Indications | Comments |
|---|---|---|---|---|---|---|
| Abbott | Perclose ProGlide | Suture | Common femoral artery 5–21 (max OD, 26); common femoral vein 5–24 (max OD, 29) | 0.038 | Common femoral artery (5–21 F) and vein (5–24 F) access sites | Provides secure repair with pretied polypropylene monofilament suture, ability to maintain wire access, minimal intravascular footprint with no reaccess restrictions; broadest indication for both femoral arterial and venous access |
| Abbott | Prostar XL | Suture | 8.5–24 | 0.038 | Common femoral artery access sites | Provides secure repair with two braided sutures, ability to maintain wire access with minimal intravascular footprint |
| Abbott | StarClose SE | Nitinol clip | 5–6 | 0.038 | Common femoral artery (5–6 F) access sites | Utilizes an extravascular nitinol clip to provide immediate repair, simple to use; hemostasis can be challenged and confirmed on the table |
Other Devices / FFR Technologies
View Chart| Company Name | Product Name | Type (Fixed Core/Movable Core) | Diameter (inch) | Length (cm) | Tip Type | Antithrombogenic (Yes/No) | Comments |
|---|---|---|---|---|---|---|---|
| Abbott | PressureWire X Guidewire | Fixed core | 0.014 | 175 | Straight | Yes, PTFE coated | Fully integrated, wireless PressureWire system when used with compatible hemodynamic systems; provides FFR measurement on Ilumien, Ilumien Optis, Optis Mobile, and Optis Integrated systems |
Other Devices / Optical Coherence Tomography
View Chart| Company Name | Product Name | Imaging Diameter (mm) | Catheter Usable Length (cm) | Maximum Guidewire (inch) | Minimum Guide Catheter ID (F) | Shaft Distal Section (F) | Comments |
|---|---|---|---|---|---|---|---|
| Abbott | Dragonfly OpStar Intravascular Imaging Catheter | 2–3.5 | 135 | 0.014 | 6 | 2.7 | Compatible with Ultreon Software and Aptivue Software (E.5.1 software or higher) |
| Abbott | Dragonfly Optis Intravascular Imaging Catheter | 2–3.5 | 135 | 0.014 | 6 | 2.7 | Works with the Ilumien, Ilumien Optis, Optis Mobile, Optis Integrated, Optis Next systems, which also include FFR measurement via the PressureWire Aeris |
Other Devices / Y-Connector/Hemostatic Valve
View Chart| Company Name | Product Name | Main Branch ID (F) | Pressure Rating (psi) | Connector Length (mm) | Bleedback Control Valve (Yes/No) | Lockable Bleedback Control Valve (Yes/No) | Rotating Valve (Yes/No) | Valve Rotations (Full Open to Full Close) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| Abbott | CoPilot | 7.3 | 400 | 77 | Yes | No | Yes | 2 | – |
More Categories:
Balloons Catheters Sheaths Stents Structural Heart Valves Wires Other Devices View AllAdvertisement