Meta-Analysis of 147 Trials Compares DES and BVS for Treating Stent Thrombosis
June 6, 2016—Si-Hyuck Kang, MD, et al published findings from a systematic review and network meta-analysis to compare the relative safety and efficacy of contemporary drug-eluting stents (DES) and bioresorbable vascular scaffolds (BVS). The study is available online ahead of print in Journal of the American College of Cardiology (JACC): Cardiovascular Interventions.
The investigators noted that the background of the study is that in seeking to improve outcomes of patients undergoing percutaneous coronary revascularization, there have been advances in the design of DES, including the development of drug-eluting BVS.
As summarized in JACC: Cardiovascular Interventions, the investigators searched online databases of prospective randomized controlled trials comparing several types of stents, including bare-metal stents (BMS), paclitaxel-eluting stents (PES), sirolimus-eluting stents (SES), Endeavor zotarolimus-eluting stents (E-ZES, Medtronic plc), cobalt-chromium everolimus-eluting stents (CoCr-EES), platinum-chromium everolimus-eluting stents (PtCr-EES), biodegradable polymer everolimus-eluting stents (BP-EES), Resolute zotarolimus-eluting stents (R-ZES, Medtronic plc), BP biolimus-eluting stents (BP-BES), hybrid sirolimus-eluting stents (H-SES; Orsiro, Biotronik), polymer-free sirolimus- and probucol-eluting stents, and BVS. The primary endpoint was definite or probable stent thrombosis at 1 year.
The investigators reported that 147 trials including 126,526 patients were analyzed in this study. All contemporary DES were superior to BMS and PES in terms of definite or probable stent thrombosis at 1 year. CoCr-EES, PtCr-EES, and H-SES were associated with significantly lower risk than BVS. CoCr-EES and H-SES were superior to SES and BP-BES. The risk of myocardial infarction was significantly lower with H-SES than with BVS. There were no significant differences regarding all-cause or cardiac mortality. Contemporary devices including BVS showed comparably low risks of repeat revascularization.
The investigators concluded that contemporary DES, including biocompatible, durable-polymer DES, BP-DES, and polymer-free DES, showed a low risk of definite or probable stent thrombosis at 1 year. BVS had an increased risk of device thrombosis compared with CoCr-EES, PtCr-EES, and H-SES. Data from extended follow-up are warranted to confirm the long-term safety of contemporary coronary devices, advised the investigators in JACC: Cardiovascular Interventions.